Troubleshooting 

 

 

System 

Possible Reasons 

Solution 

Remark 

No power input 

/power direction 

Broken fuse 

Replace 

As for authorized 

service department 

Poor connection of plug and 

Repair or replace the socket 

Содержание DZW-1200

Страница 1: ...1 Direct Cooling Type Deli Bakery Cases Installation and Operation Manual Please read this manual completely before attempting to install or operate this equipment DZW 1200 DZW 1500 DZW 1800 DZW 2000...

Страница 2: ...2 TABLE OF CONTENTS Section Page Warning 3 4 Technical Specification 4 Installation 4 5 Operation 5 8 Maintenance 8 9 Parts Breakdown 8 12 Electrical Diagram 12...

Страница 3: ...N GU A DEL PROPIETARIO ANTES DE INTENTAR DAR SERVICIO A ESTE PRODUCTO DEBEN CUMPLIR CON TODAS LAS PRECAUCIONES DE SEGURIDAD ATTENTION RISQUE DE FEU OU D EXPLOSION LE FRIGORIG NE EST INFLAMMABLE CONSU...

Страница 4: ...HP 1 3 1 3 1 2 1 2 Electrical 110V 60HZ 1P Amps 5 0 5 8 6 2 6 8 Temperature Range 33 41 F Refrigerant R290a Dimensions 47 2 x32 5 x45 2 59 x32 5 x45 2 70 8 x32 5 x45 2 79 x32 5 x45 2 Shipping Weight 5...

Страница 5: ...ress the brake on the wheels to keep it from moving 5 Fix the shelves on the unit ELECTRICAL CONNECTION Before inserting the plug into the electrical socket carefully read the following precautions 1...

Страница 6: ...on the thermostat 5 If there is some condensation in front of the curved glass please turn the switch to I position for defogging 6 Allow the unit to reach proper temperature before loading with produ...

Страница 7: ...displayed and the C or F LED starts blinking 3 To change the Set value push the or arrows within 10s 4 To memorise the new set point value push the SET key again or wait 10s 3 How to start a manual de...

Страница 8: ...a high standard of working performance leave the unit turned on during the night and day to avoid deposits CAUTION Do not use any damaging solvents petrol alcohol etc for cleaning the unit The unit ma...

Страница 9: ...Troubleshooting System Possible Reasons Solution Remark No power input power direction Broken fuse Replace As for authorized service department Poor connection of plug and Repair or replace the socke...

Страница 10: ...Repair or replace Compressor runs but the temperature in the showcase is high Circulating temperature is too high Adjust the thermostat properly Ask for authorized service department to check and too...

Страница 11: ...11...

Страница 12: ...X 0 11 AIR GUIDE BOARD 12 Front glass 138 0012 DZX 0 12 FRONT GLASS 13 Front panel 138 0013 DZX 0 13 FRONT PANEL 14 Condenser 138 0014 DZX 0 14 CONDENSER 15 Compressor board 138 0015 DZX 0 15 COMPRESS...

Страница 13: ...13 CIRCUIT DIAGRAM...

Отзывы: