TOOLCRAFT TO-7159158 Скачать руководство пользователя страница 4

Troubleshooting

Problem

Suggestions

Pulsating flow. Pump 

cycles ON and OFF.

•  Check lines for kinks.
•  Plumbing lines or fittings may be too small.
•  Clean faucets and filters.
•  Check fittings for tightness (prevent air leaks).

No pump discharge 

- failure to prime but 

motor operates.

•  Restricted inlet or discharge line.
•  Air leak in inlet line.
•  Punctured pump diaphragm.
•  Initial current supply (amps) not high enough to start the motor.
•  Debris clogging the valves.
•  Crack in the pump housing.

Motor does not 

switch ON.

•  Loose or incorrect wiring.
•  No power supplied to the pump circuit.
•  Blown fuse or thermal protection triggered.

 - Blown fuse: replace the fuse with one that is of the same type and speci-

fication.

 - Thermal protection triggered: switch power off, allow pump to cool down, 

remove the conditions triggering therrmal protection, then switch pump 

back on.

•  Failed pressure switch.
•  Damaged motor.

Pump does not 

switch on when all 

fixtures are closed.

•  Punctured diaphragm.
•  Discharge line leak.
•  Defective pressure switch.
•  Clogged valves in pump head. 

 - Try pouring water into the inlet to separate (unstick) the valve and the 

valve seat

•  Insufficient voltage.

Low flow / low 

pressure.

•  Air leak at pump inlet.
•  Accumulated debris inside pump or housing.
•  Worn pump bearing (possibly accompanied by loud noise).
•  Punctured diaphragm.
•  Damaged motor.

Noisy

•  Check if the mounting feet are screwed in too tightly.
•  If the mounting surface is flexible it may be vibrating.
•  Check for loose parts, screws.
•  If the pump is plumbed with rigid piping, it may transmit noise.

Disposal

  Electronic devices are recyclable waste and must not be disposed of in the household waste. 

At the end of its service life, dispose of the product in accordance with applicable regulatory 

guidelines.

 

You thus fulfill your statutory obligations and contribute to the protection of the envi-

ronment.

Technical data

Input voltage / current ........................... 12 V/DC, 15 A
Fuse ...................................................... 30 A
Protection class .................................... III
Ingress protection ................................. IPX5
Pressure setting .................................... 2.8 bar
Inlet pressure ........................................ max. 2 bar
Run dry safe ......................................... yes
Duty cycle ............................................. intermittent
Ignition protected .................................. no
Adjustable pressure switch ................... yes
Adjustable bypass ................................ no
Self priming ........................................... yes
Thermal protection ................................ yes
Pump type ............................................ diaphragm
Priming ................................................. 1.8 m suction lift
Fluid medium ........................................ fresh water, salt water
Fluid medium temp. .............................. max. 60 ºC
Discharge head .................................... max. 23 m
Wire lead .............................................. length: 11 cm, ø1.5 mm

2

 (16 AWG)

Flow rate ............................................... max. 1020 l/h
Hose connection ................................... ø19 mm (3/4”) 
Operating/Storage temp. ......................  0 to +40 ºC
Dimensions (W x H x D) ....................... 102 x 99 x 255 mm
Weight .................................................. 2180 g

This is a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau (www.conrad.com). All rights in-

cluding translation reserved. Reproduction by any method, e.g. photocopy, microfilming, or the capture in electronic data 

processing systems require the prior written approval by the editor. Reprinting, also in part, is prohibited. This publication 

represent the technical status at the time of printing.
Copyright 2022 by Conrad Electronic SE. 

*2386386_v3_0322_02_dh_m_en

Parts overview

a

b

c

d

A

Pump head assembly

2

Pressure switch diaphragm

B

Valve assembly

3

Pump head

C

Diaphragm assembly

4

Quick attach clip

D

Motor assembly

5

Diaphragm

1

Pressure switch

6

Rubber feet

1a Pressure adjuster

7

Motor

1b Bypass pressure adjuster
1c Inlet port (suction)
1d Outlet port (discharge)

Содержание TO-7159158

Страница 1: ... der Druck im Verhältnis zum Abschaltdruck des Druckschalters zu niedrig eingestellt schaltet sich die Pumpe nicht automatisch aus Wartung und Lagerung Überprüfen Sie regelmäßig die elektrischen Leitungen und Anschlüsse Verwenden Sie keine aggressiven Reinigungsmittel Alkohol oder andere chemische Lösungsmittel da diese zu Schäden am Gehäuse und zu Fehlfunktionen führen können Vor der Einlagerung ...

Страница 2: ...eitungs druck ist gering Vergewissern Sie sich dass an der Einlassöffnung der Pumpe keine Luft eindringt Stellen Sie sicher dass sich kein Schmutz im Inneren der Pumpe oder im Gehäuse angesammelt hat Überprüfen Sie das Pumpenlager auf Verschleiß und laute Betriebsgeräusche Überprüfen Sie die Membran der Pumpe auf Beschädigungen Überprüfen Sie den Motor auf Beschädigungen Das Betriebsge räusch der ...

Страница 3: ...d store the pump where it will not freeze Open all the ports to allow air into the pump so the water can drain out Operating Instructions Low Voltage Pressurized Water Pump 12 V 1020 l h Item No 2386386 Intended use The product is a professional grade self priming 4 chamber diaphram pump It has an automatic pressure switch that will automatically start stop the pump when a tap or valve is opened c...

Страница 4: ...sposal Electronic devices are recyclable waste and must not be disposed of in the household waste At the end of its service life dispose of the product in accordance with applicable regulatory guidelines You thus fulfill your statutory obligations and contribute to the protection of the envi ronment Technical data Input voltage current 12 V DC 15 A Fuse 30 A Protection class III Ingress protection...

Страница 5: ...hiver il est important de préparer la pompe Débranchez vidangez et rangez la pompe dans un endroit à l abri du gel Ouvrez tous les orifices pour permettre à l air d entrer dans la pompe et à l eau de s écouler Mode d emploi Pompe à eau pressurisée basse tension 12 V 1 020 l h N de commande 2386386 Utilisation prévue Ce produit est une pompe à diaphragme à 4 chambres auto amorçante de qualité profe...

Страница 6: ...uyau rigide elle peut transmettre du bruit Élimination des déchets Les appareils électroniques sont des matériaux recyclables et ne doivent pas être éliminés avec les ordures ménagères En fin de vie éliminez l appareil conformément aux dispositions légales en vigueur Ainsi vous respectez les ordonnances légales et contribuez à la protection de l en vironnement Caractéristiques techniques Tension c...

Страница 7: ...oor koud weer winter is het belangrijk om de pomp voor te bereiden Koppel de pomp los laat het leeglopen en berg het op waar het niet kan bevriezen Open alle poorten om lucht in de pomp te laten lopen zodat het water kan weglopen Gebruiksaanwijzing Laagspanning drukwaterpomp 12 V 1020 l u Bestelnr 2386386 Beoogd gebruik Het product is een zelfaanzuigende membraanpomp met 4 kamers van professionele...

Страница 8: ...dan kan deze lawaai over brengen Verwijdering Elektronische apparaten zijn recyclebaar afval en horen niet bij het huisvuil Als het product niet meer werkt moet u het volgens de geldende wettelijke bepalingen voor afvalverwerking afvoe ren Op deze wijze voldoet u aan uw wettelijke verplichtingen en draagt u bij aan de bescherming van het milieu Technische gegevens Ingangsspanning stroom 12 V DC 15...

Отзывы: