Overview
1 Motor cover
11 Screw M3*8
2 PCB board
12 Pump housing
3 PCB board bracket
13 Filter
4 Motor
14 Pipe joint
5 Motor protection cap
15 Lock nut
6 Oil seal
16 Check valve
7 Impeller
17 Wire
8 Sealing rubber ring
18 3-wire sealed connection
9 Motor cover
10 Screw sealing
Installation
IMPORTANT!
•
Never disconnect the filter while the pump is running.
•
The filter basket must be properly attached before running the pump. Do not overtighten the
screws.
•
The the thru-hull fitting should be at least 30 cm above the water line to prevent water from flow
-
ing back into the pump outlet when the pump is switched off.
1. Press the release tabs to remove the filter.
2. Determine the best location.
-
Make sure the pump cover can be removed for cleaning in this position.
-
If installing one pump, it should be placed where the water is deepest when the boat stops.
3. Attach the filter basket.
-
Attaching to wood block: use marine grade stainless steel self-tapping screws.
-
Attaching to metal or glass fiber: install a piece of wood first, then fix to the wood.
4. Connect a hose to the outlet nozzle and clamp using a marine grade stainless-steel clamp.
-
Use the standard hose size. Using a hose with smaller diameter will not damage the pump but will
restrict flow.
-
It is recommended to use a non-kink hose.
Operating Instructions
Bilge Pump with Sensor 12 V, 3.5 A, 3028 l/h
Item No. 2386388
Intended use
The product is an automatic bilge pump that dose not require a float switch. The impeller will switch on every
2.5 minutes for approximately 0.5 seconds. If the electronic sensor detects water, the pump will keep running
until the water is pumped out. Only for use with fresh water or salt water.
NOTE
•
The product has an IPX8 ingress protection rating and is suitable for outdoor use.
•
The product is sealed and submersible.
•
Please read the included safety instructions.
For safety and approval purposes, you must not rebuild and/or modify this product. If you use the product
for purposes other than those described above, the product may be damaged. In addition, improper use can
result in short circuits, fires, or other hazards. Read the instructions carefully and store them in a safe place.
Make this product available to third parties only together with its operating instructions.
This product complies with the statutory national and European requirements. All company names and prod
-
uct names are trademarks of their respective owners. All rights reserved.
Delivery content
• Pump
• Check valve
• Lock nut
• Pipe joint
• Operating instructions
Up-to-date operating instructions
Download the latest operating instructions at www.conrad.com/downloads
or scan the
QR code shown. Follow the instructions on the website.
Explanation of symbols
The symbol with the exclamation mark in
the triangle is used to indicate important
information in these operating instruc
-
tions. Always read this information care
-
fully.
This product is constructed according to
protection class III.
Not for use where flammable vapours
are present.
The arrow symbol indicates special in
-
formation and advice on operation.
Safety instructions
Read the operating instructions
carefully and especially observe
the safety information. If you do not
follow the safety instructions and
information on proper handling in
this manual, we assume no liability
for any resulting personal injury or
damage to property. Such cases will
invalidate the warranty/guarantee.
a) General information
•
The device is not a toy. Keep it out of the reach
of children and pets.
•
Do not leave packaging material lying around
carelessly. This may become dangerous playing
material for children.
•
Protect the appliance from extreme tempera
-
tures, strong jolts, flammable gases, steam and
solvents.
•
Do not place the product under any mechanical
stress.
•
If it is no longer possible to operate the product
safely, take it out of operation and protect it from
any accidental use. Safe operation can no longer
be guaranteed if the product:
-
is visibly damaged,
-
is no longer working properly,
-
has been stored for extended periods in poor
ambient conditions or
-
has been subjected to any serious transport-
related stresses.
•
Please handle the product carefully. Jolts, im
-
pacts or a fall even from a low height can dam
-
age the product.
•
Consult an expert when in doubt about the op
-
eration, safety or connection of the appliance.
•
Maintenance, modifications and repairs must
only be completed by a technician or an author
-
ised repair centre.
•
If you have questions which remain unanswered
by these operating instructions, contact our tech
-
nical support service or other technical person-
nel.
b) Connected devices
•
Also observe the safety and operating instruc
-
tions of any other devices which are connected
to the product.
c) Product
WARNING
!
•
Do not use the pump for petrol/gasonline, petro
-
leum products, solvents, thinners or ANY other
flammable liquid
•
Not for use where flammable vapours are pre
-
sent.
IMPORTANT!
•
Only use with fresh water or salt water.
•
DO NOT use with gasoline, diesel oil, hazardous, caustic, corrosive, or other flammable liquids