e) Password recovery procedure

  Contact a qualified technician if in any doubt about how to perform the password 

recovery procedure.

1. 

Switch the station OFF.

2.  Disconnect the mains cable.
3.  Disconnect tools from both channel sockets.
 

Allow all parts to cool down completely.

4.  Unscrew the 4 screws securing the front panel of soldering station.
5.  Detach the front panel with electronics from the housing.
6.  Locate the 2-pin connector marked " X10" on the back of the soldering station PCB.
7.  Put a jumper over X10 to short the 2 pins.

8.  Replace the front panel and secure it with the 4 screws.
9. 

Connect the mains cable to the power supply then switch the power ON.

 - The master reset screen will show. 
 - Message “SUCCESS !” indicates all parameters including the password has been reset 

to default values.

10. The master reset screen will appear for a few seconds followed by the active mode screen.

   If the reset procedure was interrupted, switch the power OFF then ON again to 

repeat the reset procedure.

11. When the reset procedure is complete, disconnect the station from the mains supply, disas-

semble again, remove the jumper and put back together.

Setup menu settings 

1.  From active mode, long press the   button.

   The default password is "0000". If you have not changed it, press the   button to 

enter the setup menu.

2.  Enter the password then press the   button to enter the setup menu.
3.  Select a sub menu:

Sub Menu

Description

System setup

See section "a) System setup" for details.

CH1 setup

See section "b) CH1 setup / CH2 setup" for details.

CH2 setup

See section "b) CH1 setup / CH2 setup" for details.

STORE

Select this to save any changes and return to the main screen.

4. 

Make sure you select "STORE" to save any changes.

a) System setup

Setting

Description

Language

Select German or English.

Unit

Change unit of temperature measurement (°C / °F).

Password

Change the password (default is "0000").

Brightness

Adjust the display brightness.

Beep

Turn the system sound ON/OFF.

Mode

• 

NORMAL:  Standard  regulator  adjustments  for  optimal  relation  tem

-

perature overshoot and heating time.

•  FAST: Use this regulator parameter to decrease heating time at the 

cost of higher temperature overshoot. 

Fact.Def.

Restore all settings to factory defaults.

   Important: 

All calibrations will be cleared.

EXIT

Return to previous menu

b) CH1 setup / CH2 setup

Setting

Description

Temp offset

  Make an offset adjustment if for example you use a different 

soldering tip. This function is not a substitute for calibration.

•  If the temperature (measured with external instrument) at the tip is:

 - Lower than temperature shown on the display: Adjust the offset to a 

positive value to make up difference.

 -

Higher than temperature shown on the display: Adjust the offset to 

a negative value to make up the difference. 

•  Temperature offset range: ±30 ºC (±54 ºF).
•  Default = 0.

Stdby temp

•  When a channel enters standby mode, heating will adjust to the tem-

perature set here.

•  Press any button or move the handle to exit this mode.
•  Default = 200 ºC (392 ºF).

Stdby Delay

   Setting standby delay to OFF will also switch the shutdown 

delay OFF. Any shutdown delay settings will be overridden.

•  The station will enter standby mode if no activity of the handle or but-

tons are detected for the set standby delay. 

•  Press any button or move the handle to exit this mode.
• 

Disable standby by setting to "OFF".

•  Default = 5 mins.

Shtdown delay

• 

Disable the shutdown by setting to "OFF".

•  Default = 10 mins.

Shortcut T1

•  If a shortcut temperature is set outside the 150 ºC "MIN" to 480 ºC 

"MAX" (302 to 896 ºF) temperature range, the station will accept the 

adjustment, but the shortcut will adjust to the nearest MIN/MAX tem-

perature parameter.

•  Default = 270 ºC (518 ºF).

Shortcut T2

•  If a shortcut temperature is set outside the 150 ºC "MIN" to 480 ºC 

"MAX" (302 to 896 ºF) temperature range, the station will accept the 

adjustment, but the shortcut will adjust to the nearest MIN/MAX tem-

perature parameter.

•  Default = 350 ºC (662 ºF).

Shortcut T3

•  If a shortcut temperature is set outside the 150 ºC "MIN" to 480 ºC 

"MAX" (302 to 896 ºF) temperature range, the station will accept the 

adjustment, but the shortcut will adjust to the nearest MIN/MAX tem-

perature parameter.

•  Default = 480 ºC (896 ºF).

Fix Temp

•  You will not be able to adjust the operating temperature if you set a 

fixed temperature.

•  The soldering station will override any temperature adjustments/set-

tings to maintain the fixed temperature value set for a channel.

• 

Default = OFF.

MIN Temp

•  Within the 150 ºC "MIN" to 480 ºC "MAX" (302 to 896 ºF) temperature 

range, a minimum temperature can be set.

•  Temperature adjustments or settings cannot be set below this value.
•  Default = 200 ºC (392 ºF).

MAX Temp

•  Within the 150 ºC "MIN" to 480 ºC "MAX" (302 to 896 ºF) temperature 

range, a maximum temperature can be set.

•  Temperature adjustments or settings cannot be set above this value.
•  Default = 480 ºC (896 ºF).

Legacy Hnd.

•  This station has limited support for some older analog/digital handset 

models.

•  If your handle is not detected automatically upon connection, set the 

correct handle here.

•  Available settings are: 50 W, 80 W, 100 W.

Содержание 2248468

Страница 1: ... Bei Nichtbeachtung besteht Brand und Explosionsgefahr Von der Verwendung des Produkts in unmittelbarer Nähe explosiver oder brennbarer Stoffe ist dringend abzusehen Schalten Sie das Gerät aus und legen Sie den Lötkolben auf den Ständer während Sie Pausen einlegen oder ihn nicht benutzen b Persönliche Sicherheit Arbeiten Sie nur bei ausreichender Beleuchtung des Arbeitsplatzes Achten Sie darauf da...

Страница 2: ...figurationsmenüs 1 Halten Sie während sich die Station im Betriebszustand befindet zunächst die Taste gedrückt Das in Kürze benötigte Standardpasswort lautet 0000 Haben Sie das Passwort noch nicht geändert können Sie mit einem Druck auf die Taste das Konfigurati onsmenü aufrufen 2 Geben Sie das Passwort ein und rufen Sie mit einem Druck auf die Taste das Konfigu rationsmenü auf 3 Zum Speichern der...

Страница 3: ... verloren gehen a Systemeinstellungen Einstellung Beschreibung Language Wählen Sie zwischen Deutsch oder Englisch Unit Legen Sie die gewünschte Temperatureinheit C F fest Password Ändern Sie das Passwort Standard ist 0000 Brightness Passen Sie die Helligkeit des Displays an Beep Schalten Sie den Signalton der Station EIN AUS Mode Normal Standardeinstellungen der Regelung für ein optimales Ver hält...

Страница 4: ...e Komponenten der Lötstation vollständig abkühlen Schalten Sie die Lötstation AUS und trennen Sie das Netzkabel vom Netzanschluss Verwenden Sie niemals eine Sicherung mit anderen Spezifikationen Sehen Sie auch von der Überbrückung einer defekten Sicherung dringend ab Neben der Möglichkeit eines Brandes besteht auch die Gefahr eines tödlichen elektrischen Schlages Entfernen Sie die Abdeckung über d...

Страница 5: ...e proper ventilation during soldering Solder and flux vapours can be harmful to your health Wash your hands thoroughly after working with solder This is particularly important when using lead based solder Do not put soldering alloys into your mouth Do not eat or drink during soldering Wear suitable protective clothing and safety goggles when soldering Liquid splashing solder may cause serious burn...

Страница 6: ... up in the menu Short Move down in the menu Short Accept selected item enter Long Exit menu without saving Operation a General use 1 Connect a soldering iron handle to an available tool socket then secure the connection by tightening the screw on the plug Supported handles will automatically be detected after switching the power ON Legacy handles should be set up through the setup menu See section...

Страница 7: ...is function is not a substitute for calibration If the temperature measured with external instrument at the tip is Lower than temperature shown on the display Adjust the offset to a positive value to make up difference Higher than temperature shown on the display Adjust the offset to a negative value to make up the difference Temperature offset range 30 ºC 54 ºF Default 0 Stdby temp When a channel...

Страница 8: ...te meter digital multimeter If the fuse is defective replace it with a new fuse of the same type See section Technical data Fuse Insert a replacement fuse until it clicks into place then replace the protective cover Connect the workstation to the mains and switch it back on If the fuse blows again disconnect the workstation from the mains and ask a techni cian to conduct a thorough inspection Main...

Отзывы: