Left yellow lamp „level
control“ lights, unit works
•
Not enough heat
transfer medium in the
circuit
•
Level switch defective
•
Automatic filling
defective or not
connected
•
Cool the unit below 60°C
•
Search leakage and repair it
Right (and left) yellow
lamp „level control“ lights,
unit switches off
•
Not enough heat
transfer medium in the
circuit
•
Level switch defective
•
Cool the unit below 60°C
•
Search leakage and repair it
•
Replace defective parts
The required temperature
will not be reached,
heating lamp on the
controller lights
•
Solenoid valve of the
water cooling system
not closed or defective
•
Maybe to big consumer
•
Heating defective
•
Contactor of heating
defective
•
Clean the solenoid valve,
check signal to valve and
function, repair or replace it
•
Contact the supplier
•
Measure resistance of
heating
•
Replace contactor
Lamp „cooling“ lights, unit
is not cooling
•
Cooling water inlet or
outlet is closed
•
Filter is dirty
•
Solenoid valve defective
•
Check water supply
check counter pressure on
cooling water outlet
•
Clean filter
•
Check solenoid valve
Содержание TT-188
Страница 8: ...Manual of instructions TT 188 8 37 2 Overview temperature control unit 2 1 Front view ...
Страница 13: ...Manual of instructions TT 188 13 37 4 EU Declaration of conformity ...
Страница 33: ...Manual of instructions TT 188 33 37 12 Components and spare parts 12 1 Overview components and spare parts ...
Страница 34: ...Manual of instructions TT 188 34 37 ...
Страница 38: ......
Страница 39: ......
Страница 40: ......
Страница 41: ......
Страница 42: ......
Страница 43: ......
Страница 44: ......
Страница 45: ......