![TOLSEN TOOLS 79986 Скачать руководство пользователя страница 17](http://html1.mh-extra.com/html/tolsen-tools/79986/79986_instruction-manual_1125277017.webp)
OPERATING INSTRUCTIONS
17
AIR Filter Element Maintenance
Spark plug Maintenance
1. Remove the Access Panel on the right side of the Generator.
2. Remove the Air Filter Cover and the air filter elements and check for dirt. Clean as described below.
3. Cleaning:
• For “paper” filter elements: To prevent injury from dust and debris, wear ANSI-approved safety goggles,
NIOSH-approved dust mask/respirator, and heavy-duty work gloves. In a well-ventilated area away from
bystanders, use pressurized air to blow dust out of the air filter.
• For foam filter elements: Wash the element in warm water and mild detergent several times. Rinse. Squeeze
out excess water and allow it to dry completely. Soak the filter in lightweight oil briefly, then squeeze out
the excess oil.
4. Install the cleaned filter.
5. Secure the Air Filter Cover and replace the Access Panel before use.
1. Remove Access Panel from right side of Generator.
2. Disconnect spark plug cap from end of plug. Clean out debris from around spark plug.
Spark plug maintenance cover
Screw
Air filter element
Air filter&oil
maintenance
Screw
Screw
Air filter&oil
maintenance
Screw
Содержание 79986