TOLSEN TOOLS 79986 Скачать руководство пользователя страница 12

Nominal 12VDC Output

5. Allow the engine to run for several seconds.  Wait for the output light to light up.

6. Then, move the combination switch slowly  to its run position.

NOTE:

 Moving the Combination Switch too fast could stall the Engine.

IMPORTANT:

 Allow the Engine to run at no load for five minutes with no load after each start-up so that the 

Engine can stabilize.

OPERATING INSTRUCTIONS

12

Break-in period: 

a. Breaking-in the Engine will help to ensure proper equipment and Engine operation. 
b. The break-in period will last about 30 hours of use. DO NOT exceed 75% of the Generator’s running 
wattage during this period. 
      • Change the engine oil after this period. 
          Under normal operating conditions subsequent maintenance follows the schedule explained in the      
          

MAINTENANCE

 section.

1. Do not use any 230VAC outlet while using the 12VDC outlet. 
2. Move the Economy (ECO) Switch to the OFF position. 
3. Only use the 12VDC receptacle to charge a 12 volt lead-acid type battery using an appropriate charge 

controller. (Battery and controller not included.) The 12VDC output is not regulated. 

4. Do not connect any device to the 12VDC terminal that draws more than 8.3 amps. 
5. If this 12VDC circuit protection is tripped, reduce the load, and press the Reset Button next to the outlet.

5

Move

solwly

Reset

button

12VAC

receptacle

Содержание 79986

Страница 1: ...S MANUAL You will need this manual for safety instructions operating procedures and warranty Put it and the original sales receipt in a safe dry place for future reference e n e rg y s a v in g C le a...

Страница 2: ...50ml Run Time 50 Load with full tank 6h Bore x Stroke 48 6mm x 43mm Generator Output 230VAC 50Hz 2400w 1 Phase 12VDC 8 3A 2200 Running Watts 2400 Maximum Starting Watts Receptacles 1x VDE PLUG Earthin...

Страница 3: ...s doors and vents WARNING marking concerning Risk of Fire while handling fuel Do not smoke while handling fuel WARNING marking concerning Risk of Fire Do not refuel while operating Keep flammable obje...

Страница 4: ...all applicable laws and electrical codes 7 Wear ANSI approved safety goggles heavy duty work gloves and dust mask respirator during set up 8 Use only lubricants and fuel recommended in the Specificati...

Страница 5: ...f the generator Make sure that the total electrical rating of the all of the tools or appliances plugged into the generator at the same time does not exceed that of the generator Check that the startu...

Страница 6: ...o not cover the generator during operation 33 Keep the generator and surrounding area clean at all times 34 Do not smoke or allow sparks flames or other sources of ignition around the equipment especi...

Страница 7: ...ere the insulation is cracked cut abraded or otherwise degraded Replace terminals that are worn discolored or corroded Keep terminals clean and tight 4 Do not alter or adjust any part of the equipment...

Страница 8: ...overnor and any other parts that control the fuel air ratio will need to be adjusted by a qualified mechanic to allow efficient high altitude use and to prevent damage to the engine and any other devi...

Страница 9: ...bination switch Exhaust Low oil Overload 12VDC breaker reset button 12VDC receptacle 230VAC receptacle Overload reset button Energy saving Switch Output Ground terminals Digital LCD Screen Spark plug...

Страница 10: ...Access Panel NOTICE Do not run the engine with too little oil Engine will shut off if engine oil level is too low Checking and Filling Engine Oil WARNING TO PREVENT SERIOUS INJURY FROM FIRE Fill the f...

Страница 11: ...Grip the Starter Handle of the Engine loosely and pull it slowly several times to allow the gasoline to flow into the Engine s carburetor Then pull the Starter Handle gently until resistance is felt...

Страница 12: ...T exceed 75 of the Generator s running wattage during this period Change the engine oil after this period Under normal operating conditions subsequent maintenance follows the schedule explained in the...

Страница 13: ...noverloaded 3 Disconnectallelectricaldevices andcomparedevicerequirementstoGeneratorrating Moveanythingthatmay belimitingGeneratorventilationaway 4 PressandholdOverloadResetbuttonabovetheDual120VACRec...

Страница 14: ...ombination Switch off Under normal conditions use the following procedure to shut off the Generator 1 Turn all electrical load devices off and unplug them from the Generator 2 Turn the Combination Swi...

Страница 15: ...ipment instead NOTE This maintenance schedule is intended solely as a general guide If performance decreases or if equipment operates unusually check systems immediately The maintenance needs of each...

Страница 16: ...dwithafuelstabilizer additive Followfuelstabilizer manufacturer srecommendationsforuse 5 Thenreplacethefuelcap 6 Wipeupanyspilledfuelandallowexcesstoevaporatebeforestartingengine Topreventfire donotst...

Страница 17: ...dareaawayfrom bystanders usepressurizedairtoblowdustoutoftheairfilter Forfoamfilterelements Washtheelementinwarmwaterandmilddetergentseveraltimes Rinse Squeeze outexcesswaterandallowittodrycompletely...

Страница 18: ...the spark plug can be damaged 7 Apply anti sieze material to Spark Plug threads Install the new spark plug or the cleaned spark plug into the engine Gasket style Finger tighten until the gasket contac...

Страница 19: ...or low quality gasoline 2 Engine overloaded 3 Incorrect spark timing deposit buildup worn engine or other mechanical problems 1 Fill fuel tank with fresh 87 octane stabilizer treated unleaded gasoline...

Страница 20: ...aded bolt Decorative plate Left damping pad combination Square nut Clip nut Baseplate combination Hexagon flange nut Frame shock absorber assembly Hexagon flange nut Frame shock absorber assembly 2 1...

Страница 21: ...apping screws Cross disc head self tapping screws Hexagon flange bolts 1 1 1 1 1 2 1 1 2 1 1 ASSEMBLY DIAGRAM PARTS LIST C Left cover assembly components 21 NO Description Qty 1 2 3 4 5 6 7 8 9 10 Hex...

Страница 22: ...2 1 2 2 1 E Right cover assembly components ASSEMBLY DIAGRAM PARTS LIST 22 NO Description Qty 1 2 3 4 5 6 7 8 9 10 11 12 13 Decorative board seats Decorative plate Muffler cotton Inverter components...

Страница 23: ......

Страница 24: ...kor registeredtrademarkof TOLSEN TOOLS Allrightsreserved MADE IN CHINA TOLSEN TOOLS CO LIMITED www tolsentools com e n e r g y s a v i n g C l e a n e r p o w e r p ro te c t y o u r e le c tr ic a p...