![Tolomatic 3604-9651 Скачать руководство пользователя страница 28](http://html1.mh-extra.com/html/tolomatic/3604-9651/3604-9651_hardware-installation-manual_1125252028.webp)
Tolomatic Hardware & Installation Guide:
ACS Drive/Controller
• 6-2 •
6:
S p e c i f i c a t i o n S & W i r i n g
INPUT
INPUT COMMON
24V POWER SUPPLY
INPUT SOURCED (PNP) CONNECTION
+
-
Figure 6-3: Input Source (PNP) Connection
INPUT
INPUT COMMON
INPUT SINK (SWITCHED) CONNECTION
24V POWER SUPPLY
+
-
Figure 6-4: Input Sink (switched) Connection
INPUT
INPUT COMMON
INPUT SINK (NPN) CONNECTION
24V POWER SUPPLY
+
-
Figure 6-5: Input Sink (NPN) Connection
6.2.1 Specifications
The ACS Drive has four digital outputs. These digital outputs are opto-isolated from
the drive circuitry and can be configured for sinking or sourcing. The outputs are
protected against over current and short circuit conditions. Once an over current
condition is present, the output turns off until the load is removed.
6.2 digital Outputs