Doc #0017289
Brake Monitor Operator Manual
Page 13
SECTION 6
90 DEG BRAKE TEST
Steps to perform a brake test:
1)
Set the counterbalance pressure according to the upper die weight.
2)
Put the press at top of the stroke.
3)
Put the press in continuous or single mode.
4)
Run the main motor at its fastest speed.
5)
Press 0 to activate the brake test.
6)
Run the press.
7)
When the press passes 90 degrees, the immediate stop output will open up giving
a signal to the press control to stop.
8)
Once the press comes to a complete stop, the bottom line will display the stopping
time.
9)
Brake test is complete.
To cancel a 90 Degree Brake Test, press the
<BACK>
key at any time during the
process.