VI. Operation process

2

Operation Mode

Enter correct password, press SET key to enter Setup Mode.

Press SET key

Press SET key

Press SET key

Press SET key

Press SET key

Press SET key

Press SET key

Press SET key

Setup mode (      key: shift digit,      key: modify,  SET key: confim) 

Input logic

Setting range

NPN

PNP

Default = NPN

Output mode

Setting range

F

N

C(default)

R

K

P

Q

A

M

Counting speed

Setting range(unit: Hz):

1

30

1000

5000(default)

Menu password

Have to input 4 digits password correctly, otherwise the Setting Menu

cannot be accessed (default value=0000)

Version

Menu password setting
Setting range

0000

9999

Default value = 0000

Input type

Setting range

U

D

UD-A(default)

UD-B

UD-C

Press SET key

Press SET 

key

Press SET 

key

Press SET 

key

Press SET > 3 sec

Input wrong password 

for 3 times

Decimal point
Setting range

0

3

Default value = 0

no 

decimal point

Prescale value
Setting range:
0.00001

999999

Default value = 1.00000

OUT output delay setting
Setting range: 0.01

499.99s

Default value = 1.00s

Data storage setting

Reset counting value after power failure

Remain counting value after power failure (default)

Press SET key 3 sec to confirm and exit 

Min reset time

Setting range

1

20ms

Default value = 1ms

= No lock (default)

= Lock RST key

= Lock

 

 

  key    

= Lock    

   

RST key

Key lock

Bulge

POWER

+12V

INA

CA Counter

GND

OUT

GND

Proximity 

sensor

Wheel M

POWER

A

B

GND

CA Counter

+12V

INA

INB

GND

Wheel

M

Rotary

encoder

Proximity sensor input

Rotary encoder input