VI. Operation process
2
Operation Mode
Enter correct password, press SET key to enter Setup Mode.
Press SET key
Press SET key
Press SET key
Press SET key
Press SET key
Press SET key
Press SET key
Press SET key
Setup mode ( key: shift digit, key: modify, SET key: confim)
Input logic
Setting range
:
NPN
、
PNP
Default = NPN
Output mode
Setting range
:
F
、
N
、
C(default)
、
R
、
K
、
P
、
Q
、
A
、
M
Counting speed
Setting range(unit: Hz):
1
、
30
、
1000
、
5000(default)
Menu password
Have to input 4 digits password correctly, otherwise the Setting Menu
cannot be accessed (default value=0000)
Version
Menu password setting
Setting range
:
0000
~
9999
Default value = 0000
Input type
Setting range
:
U
、
D
、
UD-A(default)
、
UD-B
、
UD-C
Press SET key
Press SET
key
Press SET
key
Press SET
key
Press SET > 3 sec
Input wrong password
for 3 times
Decimal point
Setting range
:
0
~
3
Default value = 0
(
no
decimal point
)
Prescale value
Setting range:
0.00001
~
999999
Default value = 1.00000
OUT output delay setting
Setting range: 0.01
~
499.99s
Default value = 1.00s
Data storage setting
Reset counting value after power failure
Remain counting value after power failure (default)
Press SET key 3 sec to confirm and exit
Min reset time
Setting range
:
1
、
20ms
Default value = 1ms
= No lock (default)
= Lock RST key
= Lock
、
key
= Lock
、
、
RST key
Key lock
Bulge
POWER
+12V
INA
CA Counter
GND
OUT
GND
Proximity
sensor
Wheel M
POWER
A
B
GND
CA Counter
+12V
INA
INB
GND
Wheel
M
Rotary
encoder
Proximity sensor input
Rotary encoder input