Toky CA-X Series Скачать руководство пользователя страница 3

No counting

3

U

Add

D

Minus

Input type

Illustration

Note

 A 

> minimum signal width 

 

 B 

> 1/2 minimum signal width

VII. Input Mode

Symbol

Input Type

H

L

Voltage Input (PNP)

DC 5-30V

DC 0-2V

Terminal Input (NPN)

Short Circuit

Open Circuit

UD-A

(Add/ Minus-A

Order Input

UD-B

(Add/Minus-B

Sole Input

UD-C

Phase Difference 

Input

No counting

No counting

INA: Counting Input
INB: Control Input
INB=L: INA pulse input add count
INB=H: INA forbid to count

INA: Counting Input
INB: Control Input
INB=L: INA pulse input minus count
INB=H: INA forbid to count

INA: Counting Input
INB: Control Input
INB=L: INA pulse input add count
INB=H: INA pulse input minus
            counting

INA: Control Input
INB: Counting Input
INA=H: INB pulse input add count
INA=L: INB forbid to count

INA: Control Input
INB: Counting Input
INA=H: INB pulse input minus count
INA=L: INB forbid to count

INA input pulse, add count
INB input pulse, minus count

No counting

Counting Value

Counting Value

Counting Value

Counting Value

Counting Value

Counting Value

Counting Value

 When using rotary encoder’s A, B phase output, please connect meter’s INA, INB input terminal, and set the input mode as UD-C.

INA before, INB add count
INA delay, INB minus count
Phase difference input (for rotary 
encoder)