![Tohnichi CEM10N3X8D-G-BTA Скачать руководство пользователя страница 22](http://html1.mh-extra.com/html/tohnichi/cem10n3x8d-g-bta/cem10n3x8d-g-bta_instruction-manual_1124724022.webp)
22/35
xi. Auto reset timer (Default: 0.0)
Set reset timer from 0.0
⇔
0.1
⇔
0.2
⇔
0.3
⇔
0.4
⇔
0.5
⇔
1.0
⇔
2.0
⇔
3.0
⇔
4.0
⇔
5.0 sec.
To inactivate auto reset function, select 0.0 sec.
Select the reset timer using upper or down arrow keys. Press “MEM” key to save
setting and go to next. Press “MD” key to skip setting and go to next. Press “C” key to
go back to RUN mode (measurement mode).
xii. NG data processing (Default: NG_MAN)
Select “NG_MAN” (Manual output) or “NGAUTO” (Auto output)
NG_MAN (Manual output):
When judgment result is NG the auto reset feature is declined. Press “MEM” key to
output data or “C” key to clear.
NGAUTO (Auto output):
Auto reset feature is applied even if though the judgment result is NG.
Select the mode using upper or down arrow keys. Press “MEM” key to save setting
and go to next. Press “MD” key to skip setting and go to next. Press “C” key to go back
to RUN mode (measurement mode).
xiii. Buzzer (Default: ON)
Select the buzzer turns ON or OFF for the key operations. However, over-torque alarm,
tightening completion, NG judgment alarm remains effective.
Select the buzzed is turned ON or OFF using upper or down arrow keys. Press “MEM”
key to save setting and go to next. Press “MD” key to skip setting and go to next. Press
“C” key to go back to RUN mode (measurement mode).