10/35
5. Operation examples
5.1. Tightening mode operation
Shows example on the following settings:
Ang Angle setting
ON
SEL Measurement mode setting
MODE-T
Lo
Lower limit torque setting
30N
・
m
HI
Higher limit torque setting
45N
・
m
Trg
Trigger torque setting
5N
・
m
An_d Double tightening detection angle setting
5 deg
An_L Lower limit angle setting
10 deg
An_h Higher limit angle setting
50 deg
Ar
Auto reset timer
setting
0.5
ng
NG output
setting
NG_MAN
dCn
Output format
setting
M3+ID
※
Set both the angle setting and trigger torque setting to measure the angle.
i.
Set to Peak mode (counter between "001" to "999") and start measurement.
ii.
When torque load reaches on trigger torque, starts the angle measurement.
iii.
When the tightening torque reaches to the 80% of lower limit torque, the tool
beeps intermittently while blue LED blinks to inform operator that the lower limit
torque is approaching.
iv.
When it reaches to the lower limit torque, continuous beep sound and solid blue
LED inform the completion of tightening.