5.  PRIME AND DISCHARGE 

Sucking up priming water (Automatic) 

Refer to “CONTENT   4. STARTING THE ENGINE”. 

1.

 

Press the main switch to turn on the power.  

 

 

2.

 

Press the throttle position switch“ ”.  

Then  the  throttle  position  turns  to  the  suck  up 
water position“ ”. 

 
 

3.

 

Press the start switch “ ” to run the engine.  

After starting the engine, the vacuum pump runs to 
suck up water. 

 
 

4.  After  sucking  up  water  completed,  the  vacuum 

pump stops and the throttle turns to low pressure 

position  automatically,  and  then  discharge  lamp 

turns on the light.  
The  throttle  position  turns  to  the  low  pressure 
position  after  completed  of  sucking  water  at 
automatic suction water mode just after the power 
on. 

 

If  the  pump  could  not  suck  up 
water completed in 30 seconds in 
the  auto  priming  mode,  the 
warning  lamp  lights  and  the 
warning  buzzer  sounds.  Eliminate 
the  cause  referring  “Owner’s 
manual 

of 

VE1500A-Ti/ 

TROUBLESHOOTING”. 

 

 

 

 

 

 

 

Discharge water 

status lamp 

Priming failure lamp 

Low pressure 

position 

 

Start switch / 

Low pressure throttle 

position switch 

 

Main switch 

Throttle position 

switch (“ ” position) 

 

 CAUTION

 

Содержание VE1500A-Ti

Страница 1: ...VE1500A Ti OWNER S MANUAL No 003 12086 1 REMOTE PANEL Original instructions...

Страница 2: ...Copyright 2020 Tohatsu Corporation All rights reserved No part of this manual may be reproduced or transmitted in any from or by any means without the express written permission of Tohatsu Corporation...

Страница 3: ...ange of intended uses implies that the user should follow the instructions provided by the manufacturer relevant to operation servicing and maintenance Intended people All persons who operate service...

Страница 4: ...and the control panel General safety information Before operating the TOHATSU remote control panel and the fire pump thoroughly read the manual and understand the proper operation procedures includin...

Страница 5: ...ire pump write down the serial number It will be useful in the case of asking about servicing repairs and genuine parts Serial Number The identification of remote control panel is marked on the back o...

Страница 6: ...CONTENTS 1 OPERATION DEVICE 1 2 DESCRIPTION OF DEVICES 2 3 USE OF REMOTE CONTROL PANEL 5 4 STARTING THE ENGINE 9 5 PRIME AND DISCHARGE 11 6 STOPPING THE ENGINE 13...

Страница 7: ...ry Overheat TPS WTS Throttle opening indicator Main switch Start switch Low pressure throttle position switch Throttle position switch Pressure increasing switch Pressure decreasing switch Stop switch...

Страница 8: ...onnection Turn on Unable to suck up water Water suction is not completed within 30 seconds in automatic water suction mode Engine oil shortage About 1 3 0 5L or less of the oil tank capacity Blinking...

Страница 9: ...r off Other Outlet Floodlight Only one panel outlet can be used for floodlight in connected control panels Do not connect two or more floodlights at one time Pictogram Warnings will also display by li...

Страница 10: ...ion is controlled to low pressure position Engine revolution goes down and then the throttle does not work Overheat In the case of engine temperature reaches the setting temperature of approximately 8...

Страница 11: ...ch Release the start switch immediately after the engine starts The engine running lamp turns on the light After the engine starts the vacuum pump starts running automatically and runs until sucking u...

Страница 12: ...switch While discharging water wherever the throttle position is by pressing the suction water position switch or low pressure position switch the throttle position will turn to or position When open...

Страница 13: ...or WTS failure or open circuit Warning indicator Engine opera tion Stop Stop Warning sound One time alarm ON ON ON Intermittent sound ON ON Intermittent sound ON Intermittent sound Speed control Abou...

Страница 14: ...nd the throttle does not work 4 If the battery voltage is too low such as about 7 V or less the alarm may not work Remedy A Refill the engine oil B Remove the cause of insufficient cooling water and r...

Страница 15: ...ress the start switch Low pressure throttle position switch until the engine starts The starter motor runs while pressing the switch The maximum starter running time should be 3 seconds at one time Re...

Страница 16: ...led to be maximum 3000 rpm due to avoid over speed of vacuum pump In the case of just only starting the engine with remote control panel After turning on the power press Start switch Low pressure swit...

Страница 17: ...turns to low pressure position automatically and then discharge lamp turns on the light The throttle position turns to the low pressure position after completed of sucking water at automatic suction...

Страница 18: ...tle opening level 2 Open the discharge valve s 3 Adjust the pressure of pump by pressing Increasing or Decreasing pressure switch While the engine is running pressing the start switch Low pressure thr...

Страница 19: ...3 Press the stop switch to stop the engine Then the lamps turn off Power off It takes 1 3 seconds until the engine stops owing to the after burn control This is a shut off behavior by an anti after b...

Страница 20: ...VE1500A Ti OWNER S MANUAL No 003 12086 1 5 4 Azusawa 3 Chome Itabashi Ku Tokyo 174 0051 Japan Phone 81 3 3966 3137 REMOTE PANEL...

Отзывы: