4. SYSTEM DESIGN
Prepare the required equipment according to the procedures below.
Step 1.
Determine the required number of LEDs, switches, and interlocking devices.
Step 2.
Determine whether or not the VS-900DI's talk function will be used.
If this card function is not used, use the MS-900 Master Station for conversation.
Step 3.
Determine the number of VS-910DI cards required based on the result of Step 1 above.
Tip
The VS-910DI Direct Select I/O Card has 32 calling station indication outputs, 32 direct select inputs,
and 32 external device control outputs.
Step 4.
Determine the power capacity required, and prepare the power supply.
Be sure to provide sufficient power capacity for external parts such as LEDs, in addition to the current
consumed by each card.
5. INSTALLATION
5.1. Setting the VS-900DI Station Addresses
Settings are required for both the station address and whether or not the talk function will be used. If the talk
function is not used, use the MS-900 for conversation. Perform the following setting using switch SW6.
Note
If the SW6 setting has been changed, turn OFF the unit power, then ON again.