2-1 Station Paging (for EX-610/620)
(1) The paging outputs of the PI unit must be connected to the
assigned lines of the LM unit via the station paging assign-
ment plug provided at the back of the exchange. Follow the
procedures below to make the required connections.
<For the LM-62A unit>
1. After determining the zone allocation, record it in the Station
Paging Table, part of Initial Checking Sheet for the system (CP-
62/63/64). Refer to tables 1 and 2.
2. Perform the wiring of the station paging assignment plug by
soldering according to the zone allocation determined. Refer to
Fig. 1 and Table 1.
3. Cut off unnecessary jumper wires (JP3 ~ JP8) and resistor
(R126 ~ R826) of the LM unit according to the zone allocation.
4. If the exchange is the EX-610, both No. 256 and No. 263 pins
of the assignment plug must not be connected to the GND pin.
To another
LM unit
Fig.1
Station Paging
Assignment Plug
Fig. 2 LM-62A unit
Table 1 Wiring of Station Paging Assignment Plug
Fig. 3 PI unit
Bottom
Table 2 Station Paging Connection (LM Unit)
Note:
Mark the disconnected jumper wire or resistor with "X".
-23-