10-4 Simple troubleshooting
Delimitative point for system check
A system is checked for the following delimited portions.
(5) Symptom
Cause —
No fully-duplex (simultaneous) conversation is
made when handset is lifted. (HF-200M and TL-
600).
Hook switch in printed circuit board is faulty if
state remains the same despite replacement of
station printed circuit board.
Forty Hertz (40Hz) oscillator is faulty . . . Both
conversation and dialling are possible.
Exchange check
An exchange is checked for the following delimited portions.
(1) Speech path section SG-62, DL-62A, LM-62B, PI-62, CL-62A,
TI-62,andSA-64
(2) Speech path control section CP-66, OC-62, HC-62, and HC-64
(3) Power supply section DS-610, DS-620 and DS-630
Line Check
Line faults are checked with the LED lamps of the LM. The LED
lamps light orange in an normal condition.
(1) Symptom — No LED lights up.
Cause — L1 and L2 have broken in most cases.
(2) Symptom — When a call is made, two speech links are connected
at a time.
Cause — L1 or L2 is connected to the other station.
(3) Symptom — The lamps of the LM are lighting yellow.
Cause — L1 and L2 are short-circuited.
(4) Disconnect the lines from both the exchange and station and
only check the lines for the following.
Whole system check
(1) Confirmation of numbering schedule
Points to check for numbering schedule
Are stations of the same paging group numbered consecutively?
Is the maximum number of paging groups two for the same LM
unit?
Confirm if stations are grouped correctly for calling party indica-
tion.
Confirm if the station indicated on the in/out annunciation
board by the personal number is in the correct place (office).
Confirm if the station is connected to the corresponding termi-
nal of the terminal box.
(2) Confirmation of power fuse current capacity (DS-610/620/630)
(3) Confirm if the CP DIP switches are properly set for each func-
tion.
(4) Confirm if a memory backup jumper of the CP is set to ON.
(5) Confirm if the exchange is wired properly as planned in the
station paging group numbering schedule.
(6) Confirm wiring of the paging assignment unit.
(7) Confirm the channel number of the DT-E60.
(8) Confirm if both the YR-810 and YR-801 cables are used proper-
ly.
(9) Confirm that setting the power switch to ON causes all link busy
indicators on the HC to go out.
(10) Set the front-mounted program switch of the CP to ON.
(11) Make the exchange initial setting. (Turn off the program switch
after setting.)
(12) Perform link tests.
(13) Perform speech tests by calling other stations from the station
No. 200.
(14) Turn on the CP program switch.
(15) Program each function into the exchange from the station No.
200.
(16) Perform function tests.
(17) Check battery connection.
Between the BX-610/620 and YC-601/603
Ground to station insulation (Over 1Mi7)
Insulation between lines (Over 1Mft)
Resistance (Below 100S7 for 1km with 0.65mm thick cable)
Station
A station can be divided into the following portions.
(1) Microphone circuit and amplifier
(2) Keyboard and dial signal transmitter
(3) Speaker
(4) Power supply
To find cause of failures, check for the following symptoms first
because the failures, for the most part, show such symptoms. When
there is a failure, however, first replace the station with one which
works normally. If the symptom remains unchanged, then the
trouble lies in the station or in the line. If the station replacement
causes the state to return to normal, then the trouble lies in the
station.
In-use lamp does not come on when dialled.
LED is faulty
Dialling is possible.
Power supply section is faulty
No dialling is
possible.
(1) Symptom
Cause —
(2) Symptom
Cause —
M5 (HB 1C) is faulty
Dialing is possible
No dial tone is audible when dialled.
Speaker wires are broken ... No tone.
Transformer wires are broken.
(3) Symptom
Cause —
Two stations are connected, but calling party's
voice does not reach called party.
1C of M2 is faulty . . . No dialling is possible.
Unless replacement of printed circuit board
remedies situation, microphone is faulty.
No dialling is possible.
If no signal is transmitted when dialled, M5 (HB
1C) is faulty.
If only specific keys can be dialled and replace-
ment of printed circuit board does not remedy
situation, trouble is in keyboard matrix.
Hum noise is provided.
(4) Symptom
Cause —
BX-610/620
YC-601/603
Exchange
Line
Station