Frequency Response

±ldB, 20Hz to 20kHz

Total Harmonic Distortion

Less than 0.2% at 1kHz, all sliders at 0
position, rated output

Equalization  Center Frequencies

From  31.5Hz to 16kHz
peaking type

31.5Hz (22Hz to 44Hz)
63Hz (44Hz to 88Hz)
125Hz (88Hz to 176Hz)

250Hz  (176Hz to 350Hz)
500Hz  (350Hz to  700Hz)
1kHz (700Hz to 1.4kHz)

2kHz (1.4kHz to 2.8kHz)

4kHz (2.8kHz to 5.5kHz)
8kHz (5.5kHz to 11kHz)

16kHz  (11kHz to 22kHz)

Range of Adjustment of "Q"

1.5 to 8

Equalization  Control

±12dB

Input  Level  Control

±12dB

Rated Input Level

+4dB

Rated Output Level

+4dB

Maximum Input Level

+24dB* at 1kHz

Maximum Output Level

+24dB* with 600-ohm load

Input Impedance

10k ohms

Output  Impedance

600 ohms

High Pass Filter

40Hz, 12dB/octave

Low Pass Filter

12kHz,  12dB/octave

Hum and Noise

-103dB* (EQ IN, all sliders at 0 position, A
curve by IHF)

Protect

AC fail safe

Power Consumption

E 111: 10W
E 112: 19W

Dimensions

483(W)×l33(H)×370(L) mm
19(W)×5.25(H)×l4.6(L)  inches

Weight

E 111: 7.6kg  (17 lbs)
E 112: 8.8kg (19 lbs)

Finish

Black

Indicators

Peak Indicator LED turns on at 6dB before
clipping
EQ, Power Indicators Green Color LED

Accessories

AC Cord, Cord Clamp

*0dB is referenced to 0.775 volts RMS.

— 3 —

Specifications

Appearance 

The E 111 is the same in dimension as the E 112.

Содержание E 111

Страница 1: ...Operating Instruction Manual TOA PROFESSIONAL GRAPHIC EQUALIZER Model E 111 E 112 E 112 TOA ELECTRICCO LTD KOBE JAPAN E 111 ...

Страница 2: ...ly and 220 240V AC operation with a voltage selector The voltage selector on the rear panel of the 220 240V version should be checked for proper setting prior to operation as improper setting causes trouble The voltage selector is set for 240V operation at the factory 3 Do not operate the equalizer from power mains which exceeds the indicated mains voltage by more than 10 4 Do not expose the equal...

Страница 3: ...unction provides complete equalization bypass in the event of loss of AC power and an output muting function suppresses turn on turn off transients A smoked plastic security cover is included with the E 111 or E 112 to guard against accidental disturbance or intentional tampering when used in fixed installations Inputs and outputs are transformer isolated and balanced with both XLR and 1 4 stereo ...

Страница 4: ...B Rated Output Level 4dB Maximum Input Level 24dB at 1kHz Maximum Output Level 24dB with 600 ohm load Input Impedance 10k ohms Output Impedance 600 ohms High Pass Filter 40Hz 12dB octave Low Pass Filter 12kHz 12dB octave Hum and Noise 103dB EQ IN all sliders at 0 position A curve by IHF Protect AC fail safe Power Consumption E 111 10W E 112 19W Dimensions 483 W l33 H 370 L mm 19 W 5 25 H l4 6 L in...

Страница 5: ...ESPONSE Each slider is set at a max position FREQUENCY RESPONSE ex 1kHz slider FREQUENCY FREQUENCY BANDWIDTH CONTROL ex 1kHz slider CENTER FREQUENCY CONTROL ex 1kHz slider FREQUENCY FREQUENCY 4 Performance Graphs ...

Страница 6: ...of 12dB per octave when IN Equalizer switch Placing the switch in the IN position causes the equalizer LED indicator to turn on and provides the frequency response adjusted with the EQ sliders bandwidth controls and centre frequency controls With the switch in the OUT position the equalizer LED goes out and the frequency response is flat just as the EQ sliders allow for a flat response when set to...

Страница 7: ...the fuse of same type and capacity as are instructed Power inlet An accessory power cord connects here A use of the U shaped clamp supplied with the equalizer by inserting it into the holes provided above and below the power inlet is recommended to prevent accidental disconnection of the power cord Ground lift switch The switch is used to avoid earth loop that causes hum noise when the equalizer E...

Страница 8: ... loops may cause hum and noise if care is not taken during connection An increase in noise from ground loops may be minimized by breaking the ground loop Generally the chassis ground of the signal line should be broken as shown below Rack cabinet Main AC Ground When a Y cord is used shorten the wiring to minimize noise Ground lift switches are provided on the rear of the E 111 112 Sliding the grou...

Страница 9: ...quency band is continuously variable within a range of one octave between 0 7fc and 1 4fc Thus the overall frequency response may be delicately adjusted For example if the 1kHz center frequency control has a 12dB boost the frequency response looks like that of curve 1 If the center frequency control is turned anticlockwise the response will be like curve 2 while in the case of it being turned full...

Страница 10: ...f to precisely match center frequencies with the frequencies at which feedback occurs Room Equalization In a sound reinforcement system for a room the clarity of sound can be adversely affected by the room frequency response including standing waves room resonances reflections of sound and relations between direct and indirect sound The E 111 112 are effective tools to equalize the room frequency ...

Страница 11: ...ce Piano Acoustic Piano Electric Organ Violin Brass instruments Bass drum Snare drum Tom Tom Floor Tom Hi Hat Cymbal overhead Talk Box Bass strings resonate between 70 to 120Hz body around 300Hz Avoid boosting these to stop feedback 3kHz and 5kHz gives great clarity Resonances differ depending on type Good full sounds around 300 to 500Hz Clarity at 3kHz Extreme lows are at 60 to 90Hz Pick or pluck...

Страница 12: ...TOA ELECTRICCO LTD KOBE JAPAN Printed in Japan 133 02 688 3 ...

Отзывы: