Note: CP DIP SWITCHES FOR FUNCTION SELECTION
*1 Be sure to place the SW-C-1 (Paging) switch in the ON position when paging and its allied
functions are used.
*2 To perform the "Highest Executive Priority" function in Tie-line system, place this switch of
each exchange in the ON position.
*3 Turn on this switch of each exchange even if not all the exchanges require paging function in
Tie-line system. Otherwise, the exchange with this switch off can not perform all-call paging.
*4 Selection of "Large" adds 1 more digit to the number operated.
Programming (SW-E-7 ON):
The first station number of each exchange in order of the exchanges. A, B and C can be set as
any of the following numbers:
100/200/300/400/500/600/700/800/900
(Hardwired station number)
For the personal number call, use the station number of 100s.
Exchange
Hardwired station number
A
200~455
B
470~725
C
740~995
Example:
*5 Standard (SW-E-7 OFF):
— 15 —