![Toa AX-1000A Скачать руководство пользователя страница 8](http://html1.mh-extra.com/html/toa/ax-1000a/ax-1000a_operating-instructions-manual_1122843008.webp)
2. Rear View
1. Remote Master Volume Control Terminals
Use a 10k ohm linear potentiometer (10k ohms = no gain reduction; 0 ohm = full gain reduction).
2. Direct Outputs
Individual outputs for each of the eight inputs. The signal originates at the output of the module plugged into the
port; it is not gated by the mixer.
3. Logic Outputs
To trigger external devices.
4. System Mute Terminals
5. Link In
When more than one AX-1000A is being utilized, slaves are daisy-chained using Link In/Out.
6. Link Out
7. Main Output Terminals
150/600 ohm barrier strip outputs.
8. Channel Mute DIP Switches
Chooses which channels mute in response to a short across the System Mute Terminals. As shipped the
default is 'on' (channels respond to a short across the mute terminals).
9. Mute Function Select Switch
Muting may be set for Internal Mute; INT., or for External Mute; EXT. For further details see "Using the
AX-1000A System Mute Bus".
10. Master/Slave Selector
If multiple units are incorporated in a combinable system, one AX-1000A must be the Master. The additional
units must be set up as Slaves.
11. Module Input Ports
For up to eight inputs. Each active input requires a 900 Series Module. See TOA's Input Module Instruction
Manual.
12. AC Fuse
Replace only with a fuse of the same rating. Caution: If the fuse blows, please contact TOA dealer.