background image

BASIC PARAMETERS MENU 

 

To change parameters, press and hold the 

MENU 

button for two (2) seconds. To go into the next 

indicator (parameter), press the 

MENU 

button again until you find the desired parameter.  

To change parameter value, use the 

 or 

 button. 

 

- the indicator 

 is pulsating 

– setting of desirable temperature of the heat storage tank (30 ÷ 80°C) 

- the indicator 

 is pulsating 

– activation/setting of the 

STORAGE TANK PROTECTION 

function: 

00 

– protection inactive 

10 ÷ 20 – protection active (10 ÷ 20°C) 

- the indicator 

 is pulsating 

– setting of the difference in temperatures between the collector and 

storage tank at which the pump is switched on 

(0 ÷ 30°C) 

- the indicator 

 is pulsating 

– setting of the difference in temperatures between the collector and 

storage tank at which the pump is switched off 

(0 ÷ 20°C) 

- the indicator 

 is pulsating 

– setting of the minimum pump output (20 ÷ 100%) 

 
Changes are saved and the 

MENU 

is closed when: 

- no button is pressed for 10 seconds 

- the 

MENU

 button is pressed while the bottom indicator 

 is displayed. 

 
 

COLLECTOR PROTECTION 

– ON/OFF 

 

To switch on or off the function of 

STORAGE TANK PROTECTION 

from overheating, disconnect the 

controller from the mains supply 

, press the 

START (+) 

button and, without releasing it, switch on 

the controller. The screen displays “1” to show that the protection is active or “0” to represent that the 
protection is inactive. 
 
To change the setting, use the 

START (+)

 and 

STOP (-)

 buttons. To confirm changes and resume 

operation, press the 

MENU

 button. 

 

 

SAFETY DEVICES 

 

The pump and controller are protected by means of a 500 mA fuse which blows up in emergency 
situations (e.g. short-circuit in the pump or controller).  

 

 
 

DELIVERY SET 

 

 