INSTALLATION 

 

 
1. Controller mounting 

Mount the controller on a suitable wall using  6 mm wall plugs (the plugs complete with screws are a 
part of the delivery set). 

 
2. Mounting of collector temperature sensor 

 
Mount the sensor on a non-insulated pipe going out of the collector. 
 
Fasten the sensor to the pipe using two clamps (included in the delivery set) so that they adhere 
properly to the pipe. 
 
It is advisable to wrap the pipe and the sensor with thermal insulation material. 

 
3. Mounting of heat storage tank temperature sensor 
 

Mount the sensor in a location recommended by the storage 

tank’s manufacturer. 

 
Note: The sensors are not suited for being used directly in the liquid!

 

 

4.

 

Connection of the supply cable to the pump 

 

Connect the green-yellow wire (protective neutral conductor) of the 3-wire pump supply cable to 
the protective neutral terminal of the motor (marked with an appropriate symbol); 

 

Connect the brown and blue wires to the 

and 

terminals of the pump motor; 

 

Note: Always ensure that regulator installation is performed by a properly qualified electrician.

 

 
5. Connection of the controller

 

Connect the supply cable to a 

230 V, 50 Hz power outlet

 

with an earth contact. 

The ambient temperature in the controller mounting locat

ion may not exceed 40°C. 

 

Note: The connection cable of the regulator may only be replaced by the manufacturer.

 

Note: MTS8 solar controller is only able to operate when the system is filled with water. If the 
system is empty, the controller must be disconnected from the mains supply. Otherwise the 
pump may become damaged. 
 
 
 
 

 

 