OPERATION WITH WIRELESS REMOTE CONTROL PANEL
Detailed information about the wireless remote control panel can be found in the remote control panel
manual.
JOKER CONTROLLER OPERATION WITH THE ROOM CONTROL PANEL
When the room panel is switched on, it waits for 30 seconds to be paired with the Joker main controller. If pairing is not
started within 30 seconds (parameter
G3
in the menu of the Joker - press [START]), the room panel begins displaying
measured room temperature and the "no radio communication" alert icon
(continuously).
To repeat pairing procedure, remove batteries from the room panel, reinsert them and (within 30 seconds) enter the "room
control panel" menu of the Joker main controller, select the parameter
G3
and press [START]. A "successful" or "failed"
pairing message will appear on the main screen of the Joker controller. Additionally, before pairing procedure is repeated, it
may be useful to change radio communication channel - parameter
G3
(to select channel - turn the knob).
When the room control panel and the main controller are not paired, the JOKER controller works like a version without a
room panel.
PAIRING OF THE PANEL WITH THE MAIN CONTROLLER
(parameter G3)
12
SETTING TEMPERATURE BEHIND VALVE ON THE ROOM CONTROL PANEL
.............................................................................................................................................................................................
.............................................................................................................................................................................................
In order to set temperature behind valve on the room panel for the timed programme in use (indicated by one of three
icons
) - first, unblock touch buttons and then
- press the button
- current boiler temperature will be displayed for 15 seconds;
- press the button within 15 seconds or - current setting of temperature behind valve begins flashing
and simultaneously one of two symbols will be displayed:
„L” (”low”) - means that room temperature has been reached
and that minimal temperature behind valve is edited.
„H” (”high”) - means that room temperature has not been
reached and maximal temperature behind valve is
edited.
Pressing the
or
button again will further increase or decrease setting. When setting has been changed,
after 15 seconds it will be registered and sent to the JOKER main controller.
The most important function of the room panel is to measure room temperature and to send it to the JOKER main
controller. When room temperature setting for a given time and day has been reached, the controller is working to
achieve the minimal temperature behind valve as set by the user. If room temperature has not been reached, the
controller will be working to achieve the maximal temperature setting behind valve.
Three different room temperatures may be selected: "day", "night" and "economy"
(parameter G1)
. Additionally, room
temperature may be controlled through programmed time settings, different temperatures can be set for every day of
the week and every hour (parameter
H
1). The timed programme currently in use is displayed on the MAIN SCREEN
between
When room control panel is switched off, the JOKER controller works like a version without a room panel.
the
CH pump
icon
and
the boiler return temperature.
„
LOW COAL LEVEL" ALERT ON THE ROOM PANEL
The room panel informs the user about low coal level (as set by the user) by displaying the
icon in the right bottom
corner. In addition a short audible signal is repeated every minute. The audible signal is switched off when the user has
checked coal level in the hopper (expressed in %). In order to check coal level, press and hold the
button. Parental
control does not need to be deactivated. The
icon will be displayed. The audible alert is triggered only if the timed
programme "day" is in use. The audible alert can be switched off - set the
I
5 parameter to "NO".
Description of how coal consumption is estimated is found on page
15
.