Instructions for
Installation and Use
This Pro Clear Advantage unit is supplied with two universal hosetails for
connecting the clarifier to your water supply, two blanking caps for blocking the
unused inlet/outlet, two brackets for mounting the unit and electrical
connections which are similar to those found in a domestic plug. Installation is
explained below, but please read the following safety information first.
Important Safety Information
- Please Read Carefully
- Never look directly at an illuminated UV lamp.
- Do not run this unit dry. Do not cover this unit.
- Always isolate the unit from mains electricity and turn off the water supply
before carrying out any maintenance.
- Always disconnect all pond appliances from the mains supply
before putting your hands into the water.
- Use in the area of the garden pond only if the installation complies
with the relevant wiring regulations.
- Power must be supplied through a Residual Current Device (RCD) with a
rated residual operating current not exceeding 30mA.
- This unit must be earthed. Never use a fuse larger than 3 amps.
- Rating: 220-240V, 50Hz. UV30, 35-43 watt. UV55, 50-62 watt.
Class 1. IP44.
- The unit must not be submerged in water.
- If the quartz sleeve is cracked, replace it immediately.
- The unit must be either fully frost protected or taken inside during
the winter months.
- Young children should always be supervised near water.
Product Information
- This unit is manufactured and conforms to BS EN 60335-1 and
BS EN 60335-2-55.
- This unit conforms to the low voltage directive (safety) CEE 73 23.
- This unit conforms to the EMC directive CEE 89 336.
- This unit is CE approved.
POSITIONING THE PRO CLEAR ADVANTAGE
UNIT
Pro Clear Advantage units are weatherproof but not waterproof. The unit can
be positioned either on its base on a flat surface, or attached horizontally to a
vertical surface using the brackets provided. It must not be submerged in water
or placed in a position where water may collect around the unit.
If installing the unit prior to or without a filter, it is important that a pre-filter is
used on the water pump to prevent excess solids from being pumped into the
unit. The unit may be connected to the water supply using one of the options
below:
MOUNTING ON A HORIZONTAL SURFACE
Caution:
To prevent this unit falling into water, do not install it above or
alongside your pond. Do not make the electrical connection to your unit until it
has been plumbed in and fixed securely.
If the unit is to be mounted on a flat surface the supplied blanking caps should
be screwed into the two lower inlets/outlets as shown in the diagram on the next
page.
FILTER
PUMP WITH
STRAINER
GRAVITY
FEED
PUMP WITH
STRAINER
FILTER
PRESSURIZED
FILTER
PUMP
PUMP
1
DANGER
PRO CLEAR
UV UNIT
PRO CLEAR
UV UNIT
PRO CLEAR
UV UNIT
PRO CLEAR
UV UNIT