10
IMPORTANT:
Never leave the Bayonet regulator onto the cylinder without being connected to the
appliance. The safety in case of separation or rupture of the pipe supplying gas to the consuming
appliance is not provided for being used as an open-close valve.
3.4 Checking the regulator for leaks
Never use a naked flame to check for leaks.
USE ONLY AND EXCLUSIVELY FOAM SOLUTIONS!
After installation, and any time it is necessary, check the connection of the regulator as follows:
1 Connect the regulator to the cylinder.
2. Spray the cylinder connection with combustible gas leak detector. The formation of bubbles indicates a
leak.
3. If the problem is the connection between the regulator and the cylinder the connection needs to be
checked.
4. Repeat steps 1 and 2. Check that the problem has been solved.
If it is impossible to fix the leak, remove the regulator and check that the connection is not uneven or dirty,
or that the seal is not damaged; the connection needs to be tested by a qualified technician..
If the foamy solution detects a further leak, close the regulator handle, replace the cylinder and try again.
Should there still be a leak after replacing the cylinder and carrying out the check, do not use the stove and
contact your seller (see chapter 6). Repair works or faulty component replacement must be carried out by
qualified technicians who must use original components.
ATTENTION:
Reset part no. 7
Ensure that the gas hose has enough space and is not bent. The gas hose should not be stretched or
twisted.
4
Instructions for use
4.1 Commissioning and operation
After installing the cylinder and carrying out the leak test, the gas stove can be ignited. Please follow the
instructions given here below: