TMB ProFan Скачать руководство пользователя страница 7

ProFan Operating Manual 

Attaching the Yoke Assembly 

 
1.  Place the ProFan face down upon its front grille with the hinge 

barrel side on the left and the hinge flat side on the right.  

2.  Place Item B3 flat washer upon the shank of Item B1 T-Handle, 

followed by Item B2 thrust washer and Item B4 flat washer.  

3.  Place the yoke bracket into position. Insert the shank of Item 

B1 T-Handle through the flat face hinge until the shank just 
protrudes from the flat face.  

4.  Insert Item B5 aluminum bushing between the ProFan 

housing’s tubular bracket and the yoke assembly hinge’s flat 
face.  

5.  Rotate the T-Handle clockwise until the T-Handle has 

threaded into the ProFan tubular housing bracket. Do not 
tighten completely at this point.  

6.  Place Item C2 split washer onto Item C1 Allen bolt. Place the 

Allen bolt through the barrel portion of the ProFan hinge and 
rotate the bolt until it threads into place.  

7.  Tighten the Allen bolt and the T-Handle until the yoke 

assembly is fixed and not easily moved.  

8.  At this point the ProFan is ready for mating with a stand or 

clamp. Grip the fan by its tubular housing brackets when lifting 
or mounting to avoid pinching hands or fingers. 

 

 

                   

 

B1 

A1 

C1 

C2 

B2 

B3 

B4 

B5 

Содержание ProFan

Страница 1: ...Revised 24 August 2011 Operating Manual...

Страница 2: ...Basics of DMX Control 9 DMX Data Cable 9 Cable Connectors 10 DMX Termination 10 3 Pin to 5 Pin Conversion 11 5 OPERATING INSTRUCTIONS 12 Back Pack Overview 12 Connecting the Back Pack Controller 13 D...

Страница 3: ...molded lightweight polymer the venting area is protected with rugged tubular steel The 11 one piece three blade vane and spiral front grille creates a focused wind effect ProFan applications range fr...

Страница 4: ...ProFan Operating Manual 4 Back Pack Controller Power Supply Motor Grille Body Yoke Back Panel Detail Knob Blade Knob...

Страница 5: ...with a damp cloth If fluid is spilled onto electrical components contact TMB Do not dismantle or attempt to repair a faulty machine Refer all service to TMB Do not operate the machine if the power cab...

Страница 6: ...or stood alone on its own steel yoke As delivered the ProFan is ready for stand alone use Included with the ProFan is a yoke assembly for mating the unit to a floor stand or suspension clamp The yoke...

Страница 7: ...etween the ProFan housing s tubular bracket and the yoke assembly hinge s flat face 5 Rotate the T Handle clockwise until the T Handle has threaded into the ProFan tubular housing bracket Do not tight...

Страница 8: ...igging clamps are undamaged and can support at least 10 times the weight of the unit 2 Clamp the fan to truss or similar support 3 Loosen the swivel locks and tilt the fan to the desired angle Turn th...

Страница 9: ...unison movement or operation In other words the fixtures will be slaved together and all will respond in the same way DMX fixtures are often designed to receive and transmit data through a DMX daisy c...

Страница 10: ...one end and a female XLR connector on the other end DMX connector configuration The maximum recommended DMX data link distance between fixtures is 300 meters 984 ft DMX Termination Use of a DMX termi...

Страница 11: ...cables and terminators with a continuity tester to verify correct polarity and to make sure the pins are not grounded or shorted to the shield or each other 3 Pin to 5 Pin Conversion Chart If you use...

Страница 12: ...o ProFan DMX MANUAL Mode switch LCD Display Button 1 Hold down and slide fader to set DMX address in DMX Mode 2 Press to bump to full speed in Manual Mode Slide Fader Control 1 Fan Speed Control in Ma...

Страница 13: ...ing a standard 3 pin XLR microphone cable up to 60 ft 20 m in length Attaching the Back Pack to the Fan Housing The Back Pack is secured to the fan housing by 1 two snap in clips 2 an internal magnet...

Страница 14: ...with the slot in top face of the Back Pack Once fully connected to the integral female XLR the bottom edge of the mounting bracket will snap into place fixing the bottom of the Back Pack by locating i...

Страница 15: ...signal is detected the display will then read No DMX Found To change the address of the unit press and hold the Full Speed button while adjusting the fader With the fader moved all the way up the add...

Страница 16: ...e unit is in Manual Mode The display will also indicate the current speed of the fan based on the position of the fader and whether the Full Speed button is depressed In this mode a Back Pack controll...

Страница 17: ...available pre wired from TMB Connect each controller to each fan via the XLR 3 pin line female connector Connect the 5 pin female Arnold to the 5 pin XLR male connector on the master i e first ProFan...

Страница 18: ...lace the fan behind the machines as illustrated below Do not place the fan in front of the machine This will cause residue build up on the fan blades and degrade the quality of the smoke fog or haze C...

Страница 19: ...Press button and move fader until correct address appears Power is supplied but fan does not operate via DMX In Manual Mode Switch control switch to DMX mode No Power Check power supply and connection...

Страница 20: ...t and smoke residue buildup Clean as soon as there is significant dirt buildup on fan blades or if airflow through grilles becomes restricted Use a soft brush and vacuum to clean grilles and fan blade...

Страница 21: ...or defective merchandise imperfect manufacture shortage in count or for any other defect known by the Customer to be existing at time of delivery is waived by the Customer unless made in writing withi...

Страница 22: ...0Hz ELECTRICAL Maximum power consumption 1200W Air Volume 1 700 cubic meters hr Wind Speed 60 km hr RPM 0 to 3 500 variable PERFORMANCE Acceleration Zero to full within 2 sec Protocol DMX 512A in out...

Страница 23: ...Phone 1 818 899 8818 UK Phone 44 0 20 8574 9700 e mail tmb info tmb com web www tmb com 24 7 Technical Support US Canada 1 877 TMB DUDE 1 877 862 3833 UK 44 0 800 652 5418 International 1 818 794 1286...

Страница 24: ...ProFan Operating Manual 24...

Отзывы: