ProFan Operating Manual
17
Master/Slave Operation
Up to nine ProFans can be locally controlled by one Back Pack
using a DMX data link. To link multiple ProFans, use 5-pin XLR
DMX cables between each pair of fans, as well as female and
male ProPlex "Arnold" DMX terminators on the first and last
ProFans in the chain respectively. Arnolds are wired per the ESTA
DMX512A specification and are available pre-wired from TMB.
Connect each controller to each fan via the XLR 3-pin line female
connector. Connect the 5-pin female Arnold to the 5-pin XLR male
connector on the "master" (i.e. first) ProFan Back Back controller.
Use 5-pin XLR cables to connect the master ProFan output to the
next "slave" ProFan input. Continue connecting ProFans output to
input as needed, up to nine units total. Connect the 5-pin male
DMX terminator to the DMX output of the last ProFan in the chain
Set the mode switch of the master controller to "MANUAL", and
set all the slave controllers to "DMX" at address 001.