ENGLISH
ENGLISH
30
14.
TROUBLESHOOTING
PROBLEM
ORIGIN
SOLUTION
6. Chlorides in
outlet water
(salty taste).
7. Iron in the
outgoing water.
8. Excess water
or overflow in the
salt deposit.
9. The softener
does not suction
the brine
10. Continuous
regeneration.
11. Continuous
drainage of water
into the drain or
salt tank.
12. Equipment
doesn’t perform
a bed filter
cleaning
13. Water leakage
in drain outlet.
Increase the quick wash duration.
Inadequate regeneration.
Sanitize tank. Contact with TS.
Resin dirty.
Check regeneration cycles. Increase the quick
wash duration. Sanitize. Contact with TS.
Resin dirty.
Correct refill time. Contact with TS.
Excessive refill time.
Reduce pressure to 4 bar. Contact installer or TS.
Excessive inlet pressure.
See point 9.
Insufficient brine suction.
Contact with TS.
Obstruction of the salt valve.
Contact with TS.
Inadequate injector.
Contact with TS.
Blocked programmer.
Increase pressure to 2 bar minimum.
Inlet water pressure insufficient.
Tighter connections in the suction line and verify
seal. Contact with TS.
Air in the brine suction line.
Check and/or clear drain outlet.
Exit to drain blocked.
Contact with TS.
Injector blocked.
Clean probe/valve. Contact with TS.
Aspiration valve / probe
blocked.
Replace valve main body.
Internal leak on valve.
Contact with TS.
Dirtiness inside valve.
Change the programmer. Contact with TS.
The programmer does not
function correctly.
Contact with TS.
Adjustment of the ceramic disc.
Contact with TS.
Valve blocked.
Check the electrical installation.
Failure in the electric connection.
Replace the programmer. Contact with TS.
Faulty programmer.
Reprogram the current time.
Temporal power suppy cut.
14. Toothed gear
turns constantly.
Replace electronic board and display.
Failure of electronic board.
Check internal wires.
Internal wires desconected.
Repair toothed wheel.
Toothed gear damaged.
Evacuar totalmente el aire del tanque.
There is air in the equipment.
Change the DLFC.
Too much flow on Backwash
cycle.
Replace the upper crepine.
Crepina superior dañada.
Set the by-pass in position closed until power
supply is back.
Power supply cut during
backwash or quick wash
Содержание TM63 LED