Connect the valve to the transformer, and the transfor-
mer to the power supply cord:
10.
Turn the valve by-pass by-pass position:
11.
Connect the softener drain outlet to drain the network
where you are performing the installation. Never install the
drain line directly into a grid, sewer or sump. Always allow
an air gap between the drain line and the wastewater to
prevent it from being returned to the softener.
12.
Also place a tube from the overflow outlet to drain (drain
line), to avoid possible flooding in the event of incorrect
programming, or a water leak by improper assembly, or a
valve failure. The level should be po drain below the outlet
to the overflow.
13.
Fill The salt water until half of it. Then pour a bag of salt
approximately 25 Kg The salt (use only salt tablets for water
softeners special).
When filling the tank of salt, be careful not to rub salt e nel
protection tube cane brine.
14.
Open the tap water and place the valve by-pass in
service position. Open a cold water tap nearby and let the
water run until air is removed from the softener.
Made depressurization, check the tightness of all connec-
tions. Let the water run for a few minutes to remove any
residues in the pipes.
IMPORTANT: Do not connect the overflow outlet to the drain outlet of the valve. Could cause accidental
filling of the brine tank and cause flooding. So, install two separate tubes.
By-pass
position
Air space
Drain
Maximum level
Middle level
Minimum level