background image

 

172-65256M-00  (VFM-T2)  7 Sep 2001

 

11

 

Internal Construction 

For pulse type, the motherboard is of 2-board construction, containing a “display 
board” and a “power board”. Analog type (optional) is of 3-board construction, 
containing the addition of an “F/I board”. The power board and F/I board are 
connected by individual connectors to the display board. 

The external connection terminals are found on the rear of the counter. 

 

 

 
 

Removing the Internal Components 

 

<Caution> Be sure to perform this operation with the power supply turned 
OFF. 

 
NOTE: Disconnect all wiring from the counter unit.

 

 

 

 

 

 

 

 

 

1) Remove the panel-mount 
fitting, and then pull the unit out 
from the front of the panel. 

2) Remove the screws from 
the rear plate, and then take 
the rear plate off. 

3) Pull the internal unit 
out to the rear. 

 

Waveform Shaping Function 

Specifications for Type of Pulse Input and Input Settings 

Jumper Set Points 

Type of Pulse 

Input 

J2 

J5 

J1 

J3 

J4 

Power to 

Transmitter 

Input 

Impedance 

Current Pulse  3 – C  Uncoupled 

*1 

*2 

*3 

24V DC 

510

 

NOTE: *1: Couple to increase the waveform shaping filter approximately 10 times. 

*2: This jumper is used to select the pulse output specifications.   

Synchronized input (1/1)  : A – C 

Scaled (display units)     : B – C (STD.) 

→→

 See the next section. 

*3: A microprocessor input speed with a maximum of 200Hz is required. It may 

be necessary to set “hard” dividing prior to the processor input. Divide by 
one of the following: 1/1, 1/10 or 1/100.     

 

 

 

→→

 See the next section.   

F/I Board (Optional) 

Terminal Blocks

Display Board 

Power Board 

Panel-mount Fitting

 

Rear Plate

 

Internal Unit

 

Содержание VFM-T2

Страница 1: ...65256M 00 VFM T2 7 September 2001 Vortex Flowmeter Counter VFM T2 Copyright 2001 by TLV CO LTD All rights reserved ISO 9001 ISO 14001 Manufacturer Kakogawa Japan is approved by LRQA LTD to ISO 9001 14...

Страница 2: ...g Terminal Block 7 Input Signal Connection 7 Configuration Block Diagram 8 Functions and Operation 9 The LCD Counter Display 9 Verifying the Meter Factors 9 Calculating Total and Instantaneous Flow Ra...

Страница 3: ...pearance to make sure nothing is out of the ordinary Also be sure to read this manual carefully before use and follow the instructions to be sure of using the product properly If detailed instructions...

Страница 4: ...r damage occurring as a result of failure to observe these precautions Symbols Indicates a DANGER WARNING or CAUTION item DANGER Indicates an urgent situation which poses a threat of death or serious...

Страница 5: ...rt where at all possible transport the product to the installation site in the original packaging in which it was shipped from TLV 2 During transport avoid subjecting the product to strong impacts or...

Страница 6: ...croprocessor and is lightweight and compact in design It offers four independent functions cumulative total flow instantaneous flow rate hourly and per minute total flow and resettable total in a sing...

Страница 7: ...o injury fires damage or other accidents may occur Do not touch the terminals during transmission Failure to observe this precaution could result in such hazards as damage to the product malfunctions...

Страница 8: ...m Caution As incorrect combinations could lead to serious damage to these units be sure to check again after connecting the cables Description of Field Wiring Terminals Name Terminal No Connection and...

Страница 9: ...cuit in the next step When the full scale frequency is in the range of 2 4Hz and the waveform ratio of the input pulse is 1 1 J1 CLOSE F I Circuit converts an input frequency of 4 20mA or 1 5V to an a...

Страница 10: ...sequence Verifying the Meter Factors If the MODE button is pushed when the select switch is set to either C or 4 the meter factors are displayed in the following sequence NOTE For items marked with a...

Страница 11: ...rate in full scale is held within 1 100 T 200ms NOTE It is designed so that when T 5000 ms the instantaneous flow rate on the display will show 0 NOTE Set it so that sampling cycles input period 5000...

Страница 12: ...ove the screws from the rear plate and then take the rear plate off 3 Pull the internal unit out to the rear Waveform Shaping Function Specifications for Type of Pulse Input and Input Settings Jumper...

Страница 13: ...ith the individual specifications Setting the Pulse Output Specifications Selection Jumper J3 1 Synchronized input 1 1 A C 2 Scaled display units standard B C Power Board underside Setting Hard Dividi...

Страница 14: ...manner only the procedure for the meter factor is explained here to avoid duplication Ex Changing the meter factor from 1 2345 to 0 9876 1 Change the position of the select switch from the default pos...

Страница 15: ...3 Verifying the New Meter Factor Setting Change the select switch from F to C and press the MODE button to confirm each individual digit The new meter factor Ex is displayed 14 Change the select switc...

Страница 16: ...fixed l l Set the pulse width to a suitable flow rate range to ensure that the pulse does not become too heavy Operation and Adjustment for Setting and Modifying the Analog Output Circuit Optional The...

Страница 17: ...09 9 B 110 0 119 9 C 120 0 129 9 D 130 0 139 9 E 140 0 149 9 F ON ON ON ON 150 0 199 9 2 OFF OFF OFF OFF 200 0 299 9 3 OFF 300 0 399 9 4 ON 400 0 499 9 5 500 599 6 600 699 7 700 799 8 800 899 9 900 99...

Страница 18: ...onse Operation After pre operational preparations are completed turn on the power Troubleshooting u IMPORTANT u When internal trouble is suspected contact TLV after inspecting the counter by following...

Страница 19: ...to 1 10 or 1 100 When scaler value exceeds 1 150Hz maximum Selection Scaled same unit as displayed standard or synchronized input unscaled Output Signal Open collector after optical isolation Capacity...

Страница 20: ...improper installation use handling etc by other than TLV CO LTD authorized service representatives Malfunctions due to dirt scale rust etc Malfunctions due to improper disassembly and reassembly or i...

Отзывы: