Model
L
Applicable Steam Trap Model
D
W
H
RK4
SS3N/SS3V
mm
160
(in)
( 6
)
16
5
/
( 1
)
4
3
/
( 3
)
16
9
/
( 3
)
16
15
/
15 ( )
16
9
/
6 ( )
4
1
/
70 (2 )
4
3
/
150 (5 )
8
7
/
220 (8 )
16
11
/
mm
45
(in)
mm
90
(in)
mm
100
(in)
(Insulation Cover)
(Binding Strip
×
2 pcs)
Model
Velcro Strip
W
H
Unit: mm (in)
φ
D
L
9. Optional Insulation Cover on SS3N and SS3V
The insulation cover (glass mat/glass fiber cloth) is available as an option.
Install according to the following steps.
1. Allow the trap to cool to ambient temperature.
2. Open the cover along the Velcro strip.
3. Place cover evenly around the body with the arrow on the cover facing the same direction as
the arrow on the trap body.
4. Reattach the Velcro strip.
5. Secure the ends of the cover around the trap inlet and outlet with the binding strips.