background image

 

  Free Float Drain Trap  

SS1VA

 

 

Thank you for purchasing the 

  Free Float Drain Trap for air 

and inert gases. 
This product has been thoroughly inspected before being shipped 
from the factory. When the product is delivered, before doing 
anything else, check the specifications and external appearance to 
make sure nothing is out of the ordinary. Before beginning 
installation or maintenance, please read this manual to ensure 
correct usage of the product. 
This instruction manual is needed not only for installation, but for subsequent 
troubleshooting. Please keep it in a safe place for future reference. 
The contents of this manual are subject to change without notice. 

 

1. Safety Considerations 

DO NOT use for toxic, flammable or otherwise hazardous fluids.  This 

product is a drain trap that discharges condensate from air or inert gas 

systems.  Use only for air or inert gas.  This product is for intended use 

only.  Improper use may result in such hazards as damage to the 

product or malfunctions that may lead to serious accidents.

WARNING

 

 

 

NEVER apply direct heat to the float. The float may explode due to 

increased internal pressure, causing accidents leading to serious injury 

or damage to property and equipment.

 

WARNING 

 

 

Install properly and DO NOT use this product outside the recommended 

operating pressure, temperature and other specification ranges. 

Improper use may result in such hazards as damage to the product or 

malfunctions which may lead to serious accidents. Local regulations 

may restrict the use of this product to below the conditions quoted.

 

CAUTION 

 

 

DO NOT use this product in excess of the maximum operating pressure 

differential; such use could make discharge impossible (blocked).

 

CAUTION 

 

 

Take measures to prevent people from coming into direct contact with 

product outlets. Failure to do so may result in burns or other injury from 

the discharge of fluids.

 

CAUTION 

 

 

When disassembling or removing the product, wait until the internal 

pressure equals atmospheric pressure and the surface of the product 

has cooled to room temperature. Disassembling or removing the 

product when it is hot or under pressure may lead to discharge of fluids, 

causing burns, other injuries or damage.

 

CAUTION 

 

 

Be sure to use only the recommended components when repairing the 

product, and NEVER attempt to modify the product in any way. Failure to 

observe these precautions may result in damage to the product or burns 

or other injury due to malfunction or the discharge of fluids.

 

CAUTION 

 

 

Use only under conditions in which no freeze-up will occur. Freezing 

may damage the product, leading to fluid discharge, which may cause 

burns or other injury.

 

CAUTION 

 

 

Installation, inspection, maintenance, repairs, disassembly, adjustment 

and valve opening/closing should be carried out only by trained 

maintenance personnel. 
 

CAUTION 

 

 

 
2. Specifications

 

Refer to the product nameplate for detailed specifications. 

 

* Maximum allowable pressure 

(PMA) and maximum allowable 
temperature (TMA) are 
PRESSURE SHELL DESIGN 
CONDITIONS (

NOT

 

OPERATING CONDITIONS) 

** Valve No. is displayed for 

products with options. This item 
is omitted from the nameplate 
when there are no options.

 

Minimum Required Condensate Load: 

For SS1VA-M with a metal valve seat, a minimum 

required condensate load of 0.5 kg/h (1 lb/h) is necessary to maintain a liquid seal. There is a 
chance of air/gas leak if the condensate load falls below this rate. 

 

 
3. Configuration 

 

No.  Name 

No.  Name 

1  Body 

7  Cover Gasket 

2  Cover 

8  Cover Bolt 

3  Float 

9  Nameplate 

4  Valve Seat (Orifice) 

10  Flange 

Valve Seat (Orifice) 
Gasket 

11  Screw 

12  Spring Washer 

6  Screen 

13  Connector 

 

                          

 

 
4. Proper Installation

 

1. Before installation, be sure to remove all 

protective seals. 

2. Before installing the product, open the inlet 

valve and blow out the piping to remove any 
piping scraps, dirt and oil. Close the inlet 
valve after blowdown. 

3. Install the product so the arrow on the body 

is pointing in the direction of flow.

 

 

4. To prevent air binding, inlet piping must be 

straight, vertical, as short as possible and 
with a minimum nominal diameter of 15 mm (

1

/

2

 in). If a length of horizontal piping 

between the equipment and the product is unavoidable, the horizontal piping must be 
kept as short as possible. If it exceeds 200 mm (8 in), a pressure-balancing line must 
be installed (see right). 

5. The product must be installed vertically, inclined no more than 5° horizontally and 

front-to-back. 

6. Install a condensate outlet valve and outlet piping.   
7. Open the inlet and outlet valves, make sure that the product functions properly. 

 

 
5. Inspection and Maintenance 

Operational Check: 

A visual inspection of the following items should be done on a 

daily basis to determine whether the product is operating properly or has failed.   
Periodically (at least biannually) the operation should also be checked by using 
diagnostic equipment, such as a stethoscope or thermometer. 

If the product should fail, it may cause damage to piping and equipment, resulting in 
faulty or low quality products or losses due to air or gas leakage. 

When parts have been removed, or during periodic inspections, use the table to the 
right to inspect the parts and replace any that are found to be defective. 
 

Gaskets: check for warping or damage 

Screen: check for clogging, corrosion or damage 

Valve Seat: check for clogging, warping or scratches 

Float: check for scratches, dents or water inside the float 

Body, Cover: check for damage or build-up inside 

 

 

6. Disassembly / Reassembly

 

 

Use the following procedures to remove components. Use the same procedures in 
reverse to reassemble. If drawings or other special documentation were supplied for the 
product, any torque given there takes precedence over values shown here. 

Part 

During Disassembly 

During Reassembly 

Cover Bolt 

Remove with a 17 mm (

21

32

 in) 

socket wrench 

Coat threads with anti-seize; tighten to a 
torque of 45 N

m (33 lbf

ft) 

Cover 

Remove; take care to prevent 
any damage to the float, which 
may fall out when the cover is 
removed   

Make sure there are no pieces of the old 
gasket left on the sealing surfaces, then 
reattach; be careful not to bend the float 
guides (Fig. A) 

Float 

Remove being careful not to 
scratch the polished surface 

Place inside body, being careful not to 
scratch or misshape 

Connector 

Remove 

Insert into hole in cover 

Cover Gasket 

Remove gasket and clean 
sealing surfaces 

Replace with a new gasket if warped or 
damaged, do not apply anti-seize 

Valve Seat 

Remove with a 13 mm (

1

/

2

 in) 

socket wrench 

Coat threads with anti-seize; tighten to a 
torque of 15 N

m (11 lbf

ft) 

Valve Seat 
Gasket 

Remove gasket and clean 
sealing surfaces 

Replace with a new gasket if warped or 
damaged, apply anti-seize 

Screw & 
Washer 

Remove with a Philips 
screwdriver 

Tighten to a torque of 0.3 N

m (0.22 lbf

ft) 

Screen 

Remove without bending 

Insert the screen with the proper orientation, 
aligning screw holes (Fig. B)   

(1 N

 10 kg

cm)

 

 

Figure A

 

Note: Do not change 
the position of the 
float guides. Tight 
sealing cannot be 
guaranteed if the float 
guides have been 
moved out of position. 

 

Figure B 

 

 

 
7. Troubleshooting 

When the product fails to operate properly, use the following table to locate the cause. 

Problem 

Cause 

Remedy 

No condensate is 
discharged 
(blocked) or 
discharge is poor 
 

The float is damaged or filled with 
condensate 

Replace with a new float 

The valve seat opening, screen or piping 
are clogged with rust and scale 

Clean parts 

The trap operating pressure exceeds the 
maximum specified pressure, or there is 
insufficient pressure differential between 
the trap inlet and outlet 

Compare specifications and 
actual operating conditions 

Air binding has occurred 

Correct the installation   
(see “Proper Installation”) 

The specific gravity of the fluid is not 
suitable for this product 

Consult TLV 

Air/gas is 
discharged or 
leaks from the 
outlet* 
(blowing)   
(air/gas leakage) 

Rust and scale have built-up around the 
valve seat or beneath the float 

Clean parts 

The valve seat is scratched or damaged 

Replace with a new valve 
seat 

The float is deformed or has a build-up 

Clean or replace with a new 
float 

Improper installation orientation 

Correct the installation 

There is excessive trap vibration 

Lengthen the inlet piping and 
fasten it securely 

Air/gas is leaking 
from a place other 
than the outlet 

Gasket(s) are deteriorated or damaged 

Replace with new gasket(s) 

Improper tightening torques were used 

Tighten to the proper torque 

* SS1VA-M with metal valve seat requires a minimum condensate load of 0.5 kg/h (1 lb/h) to 

prevent any air/gas leak 

 

 

Manufacturer 

 

 

881 Nagasuna, Noguchi, Kakogawa, Hyogo, 675-8511 Japan 
Tel: [81]-(0)79-422-1122  Fax: [81]-(0)79-422-0112 

Copyright © 2017 by TLV Co., Ltd. All rights reserved 

Rev. 3/2017 (T)

SS1VA-M 

(with metal valve seat) 
 

Nominal Diameter 

Production Lot No. 

Valve No.** 

Maximum Allowable Pressure* 

Max. Allowable Temperature* 

Max. Operating Temperature 

Model 

Maximum Differential Pressure 

Screw & Washer 

Screen 

Float Guides 

Connector 

Cover 
Gasket 

Standard 

Requiring   

Balancing Line 

 

 

 

 

 

 

Pressure-balancing Line 
 

Inlet Piping 
 
 

INSTRUCTION MANUAL 

Keep this manual in a safe place for future reference

 

SS1VA-R

 

(with rubber valve seat) 
 

 

 

 

 

 

Отзывы: