172-65126MA-10 (FLl5/FL21/FL32/FL5-C/FL21-C/FL32-C + BD2) 10 Mar 2017
5
Specifications
Install properly and DO NOT use this product outside the recommended
operating pressure, temperature and other specification ranges.
Improper use may result in such hazards as damage to the product or
malfunctions which may lead to serious accidents. Local regulations
may restrict the use of this product to below the conditions quoted.
CAUTION
Use only under conditions in which no freeze-up will occur. Freezing
may damage the product, leading to fluid discharge, which may cause
burns or other injury.
CAUTION
The pressure and temperature values displayed on the nameplate of the
connector body are the values for the connector body itself and not for
the entire trap. Improper use may result in such hazards as damage to
the product or malfunctions that may lead to serious accidents.
CAUTION
Refer to the product nameplates on the trap unit AND on the connector body for detailed
specifications.
The specifications displayed on each nameplate apply only to the unit on which it is
mounted. When a trap unit is installed on a connector unit and the PMA/TMA and/or
PMO/TMO values displayed on the two nameplates differ, the specifications for the
assembled products are restricted to the lower values.
Trap Unit
Production Lot No.
Valve No.**
Model
Maximum Allowable
Temperature (TMA)*
Nominal Diameter***
Maximum Operating
Temperature (TMO)
Maximum Allowable
Pressure*
Maximum Operating
Pressure
X-element Type
Connector Unit (mounted only on F46)
Model
Maximum Allowable
Temperature (TMA)*
Maximum Operating
Temperature (TMO)
Nominal Diameter
Maximum Allowable
Pressure*
Production Lot No.
Maximum Operating
Pressure
* Maximum allowable pressure (PMA) and maximum allowable temperature (TMA) are PRESSURE SHELL
DESIGN CONDITIONS,
NOT
OPERATING CONDITIONS.
** Valve No. is displayed for products with options. This item is omitted from the nameplate when there are
no options.
*** The nominal diameter is not printed on the trap unit nameplate when the trap unit is shipped by itself.
Maximum Operating Temperature
0.5
(75)
(482)
(464)
(392)
(302)
(212)
(455)
(437)
240
°
C
235
°
C
225
°
C
250
220
200
150
100
1.0
(150)
1.5
(215)
2.1
(300)
2.5
(350)
3.0
3.2
(450)
0
FL32/FL32-C, L32/L32-C
FL21/FL21-C, L21/L21-C
FL5/FL5-C, L5/L5-C
Saturated Steam Curve
Operating Pressure MPaG (psig)
T
em
per
at
ur
e
°
C (
°
F
)