172-65230A-06 (LV6) 23 May 2019
7
Maintenance
Take measures to prevent people from coming into direct contact with
product outlets. Failure to do so may result in burns or other injury from
the discharge of fluids.
CAUTION
Be sure to use only the recommended components when repairing the
product, and NEVER attempt to modify the product in any way. Failure to
observe these precautions may result in damage to the product or burns
or other injury due to malfunction or the discharge of fluids.
CAUTION
Operational Check
A visual inspection of the following items should be done on a daily basis to determine
whether the product is operating properly or has failed. Periodically the operation
should also be checked by using diagnostic equipment such as a stethoscope,
thermometer, TLV Pocket TrapMan or TLV TrapMan.
If the product should fail, it may cause damage to piping and equipment, resulting in
faulty or low quality products or losses due to steam leakage.
Normal
: During either intermittent or continual condensate discharge
flash steam is discharged and the sound of flow can be heard.
Blocked
(Discharge
Impossible)
: No condensate is discharged. The trap is quiet, making no
noise, and the surface temperature of the trap is low.
Blowing
: Live steam continually flows from the outlet and there is a
continuous metallic sound.
Steam Leakage : Live steam is discharged through the trap outlet together with
condensate, accompanied by a high-pitched sound.
Parts Inspection
When parts have been removed, or during periodic inspections, use the f ollowing table
to inspect the parts and replace any that are found to be defective.
Procedure
Gasket: check for warping or damage
X-element valve area and valve seat area of body: check for
scratches, foreign matter or oil film
Body interior: Check for build-up, oil film, scratches and wear