172-65457MA-02 (JH7.2R-X) 14 Jul 2015

 

12

 

3

5

6

Gasket

Do not pinch gasket

in thread recesses

4

Coat with anti-seize

Gasket Surface

 

Instructions for Plug / Holder Disassembly and Reassembly

 

The seal on the threaded plugs/holders found on TLV products is formed by a flat 
metal gasket. There are various installation orientations for the gaskets, such as 
horizontal, diagonal and downward, and the gasket may be pinched in the thread 
recesses during assembly. 

 

Instructions for Disassembly and Reassembly 

 

Remove the plug/holder using 
a tool of the specified size 
(distance across flats). 

 

The gasket should not be 
reused. Be sure to replace it 
with a new gasket. 

 

Clean the gasket surfaces of 
the plug/holder and the product 
body using a rag and/or 
cleaning agents, then check to 
make sure the surfaces are not 
scratched or deformed. 

 

Coat both the gasket surface 
of the plug/holder and the 
threads of the plug/holder with 
anti-seize, then press the 
gasket onto the center of the 
gasket surface of the 
plug/holder, making sure the 
anti-seize affixes the gasket 
tightly to the plug/holder. 
Check to make sure the 
gasket is not caught in the 
recesses of the threads. 

 

Hold the plug/holder upside down to make sure that the anti-seize makes the 
gasket stick to the plug/holder even when the plug/holder is held upside down. 

 

Screw the plug/holder by hand into the product body while making sure that the 
gasket remains tightly affixed to the center of the gasket surface of the 
plug/holder. Make sure the entire gasket is making contact with the gasket 
surface of the product body. It is important at this point to make sure the gasket 
is not pinched in the thread recesses of the plug/holder. 

 

Tighten the plug/holder to the proper torque. 

 

Next, begin the supply of steam and check to make sure there is no leakage 
from the part just tightened. If there is leakage, immediately close the inlet valve 
and, if there is a bypass valve, take the necessary steps to release any residual 
pressure. After the surface of the product cools to room temperature, repeat the 
procedure beginning from step 1. 

 

Содержание JH7.2R-X

Страница 1: ...A 02 JH7 2R X 14 July 2015 Free Float Steam Trap with X element JH7 2R X Copyright 2015 by TLV CO LTD All rights reserved ISO 9001 ISO 14001 Manufacturer Kakogawa Japan is approved by LRQA LTD to ISO...

Страница 2: ...s steam trap is also of a revolutionary design featuring an integral air vent that employs a high performance X element The X element is very sensitive to changes in temperature and responds with grea...

Страница 3: ...eat of death or serious injury WARNING Indicates that there is a potential threat of death or serious injury CAUTION Indicates that there is a possibility of injury or equipment product damage WARNING...

Страница 4: ...recommended components when repairing the product and NEVER attempt to modify the product in any way Failure to observe these precautions may result in damage to the product and burns or other injury...

Страница 5: ...back pressure has a check valve TLV CK been installed 5 Is the inlet pipe as short as possible with as few bends as possible and installed so the liquid will flow naturally down into the trap 6 Has th...

Страница 6: ...densate level causes the float to rise due to buoyancy opening the orifice B and allowing condensate to be discharged 3 Hot Air Discharge Should hot air flow into the trap with the steam during normal...

Страница 7: ...meplate for detailed specifications Model Maximum Allowable Temperature TMA Maximum Allowable Pressure Nominal Diameter Maximum Differential Pressure Production Lot No Valve No Maximum Operating Tempe...

Страница 8: ...he discharge of fluids CAUTION Installation inspection maintenance repairs disassembly adjustment and valve opening closing should be carried out only by trained maintenance personnel 1 Before install...

Страница 9: ...flash steam and the sound of flow can be heard If there is very little condensate there is almost no sound of flow Blocked Discharge Impossible No condensate is discharged The trap is quiet and makes...

Страница 10: ...s and tighten to the proper torque Drain Plug Gasket Remove the gasket and clean sealing surface Replace with new gasket coat surfaces with anti seize Detaching Reattaching the Cover Part During Disas...

Страница 11: ...ult the table of tightening torques and tighten to the proper torque Orifice Plug Gasket Remove the gasket and clean sealing surface Replace with a new gasket coat surfaces with anti seize Orifice Rem...

Страница 12: ...Exploded View Drain Plug Gasket Cover Cover Nut Cover Bolt Cover Gasket Screen holder Drain Plug Orifice Body Screen Float Orifice Gasket Orifice Plug Gasket Orifice Plug X element Guide Air Vent Valv...

Страница 13: ...gasket onto the center of the gasket surface of the plug holder making sure the anti seize affixes the gasket tightly to the plug holder Check to make sure the gasket is not caught in the recesses of...

Страница 14: ...maximum specified pressure or whether there is insufficient pressure differential between the trap inlet and outlet Compare specifications and actual operating conditions Steam is discharged or leaks...

Страница 15: ...oper installation use handling etc by other than TLV CO LTD authorized service representatives 2 Malfunctions due to dirt scale rust etc 3 Malfunctions due to improper disassembly and reassembly or in...

Страница 16: ...e valve insert a flat head screwdriver into the slot on the top of the needle valve and Open Valve slowly turn counterclockwise Do not continue turning the needle valve past the point at which the sna...

Страница 17: ...MPa Discharge Capacity kg h Differential Pressure kg cm 2 More than 1 5 turns 1 Turn Turn Turn Turn Number of turns from full closed position Differential Pressure psi Discharge Capacity lb h More th...

Отзывы: