EF200W-C
16
Connecting cable for remote version
Transmitter and sensor connection housing
In the case of the remote version, the sensor and transmitter are mounted separately from on
another and connected by a connecting cable. Connection is performed via the sensor connection
housing and the transmitter housing.
Terminals are always used to connect the connecting cable in the sensor connection housing
(tightening torques for screws for cable strain relief: 1.2 to 1.7 Nm).
Connecting cable
+
‒
+
‒
2
1
1
2
1
2
3
4
1
2
3
4
GN
YE
WH
BN
A0033476
Terminals for connection compartment in the transmitter wall holder and the sensor connection housing
1
Terminals for connecting cable
2
Grounding via the cable strain relief
Terminal number
Assignment
Cable color
Connecting cable
1
Supply voltage
Brown
2
Grounding
White
3
RS485 (+)
Yellow
4
RS485 (‒)
Green