4
Specifications
DO NOT use this product outside the recommended operating pressure,
temperature and other specification ranges. Improper use may result in
such hazards as damage to the product or malfunctions which may
lead to serious accidents. Local regulations may restrict the use of this
product to below the conditions quoted.
Use only under conditions in which no freeze-up will occur. Freezing may
damage the product, leading to fluid discharge, which may cause
burns or other injury.
Valve
Model
CV5
Body material
Cast Iron
Cast Steel
Connection
Flange
Size
15
20
25
32
40
50
15
20
25
32
40
50
PMO (MPaG)
1.3
1.0
2.5
1.7 1.0
TMO (MPaG)
200
220
Seat Plug Sealing
Metal Sealing
Characteristic
Equal Percentage
Rangeability
50 : 1
Leakage Class (IEC534-4)
Class
Ⅳ
Actuator
Actuator Area (cm2)
120
Fail-safe Position
Air to open
Air to close
Bench Range (MPa)
0.04 – 0.14
0.21 – 0.33
Electrical Input Signal (mA)
4 – 20
Air Supply Press. (MPaG)
MAX. 0.6
Transit Time for Rated Travel
Approx. 3 seconds
Hysteresis (%)
<1
Protection Class
IP54
Ambient Temp. Range
-30 – 70
Motive Medium
Oil-free air, filtered 5
μ
m
* Maximum allowable pressure (PMA) and maximum allowable temperature (TMA) are PRESSURE SHELL
DESIGN CONDITIONS,
NOT
OPERATING CONDITIONS.