7
TEG-BE8H-M-00 20 August 2013
Fault
Possible reason
Remedy
Seat or disc damage
Replace the valve and contact the
supplier or TLV
Pressure difference too great
Apply valve with balancing disc.
Check if the valve was installed
according to direction of arrow
marked on the valve.
Seat leakage
Medium polluted with solid
particles
Clean the valve. Fit strainer
before the valve.
Broken connecting
flange
Bolts tightened unevenly
Replace the valve with new one
11. Disposal
Obsolete and dismantled valves must not be disposed of with household waste. This
product is made of materials which can be re-used and should be delivered to
designated recycling centers.
12. Product Warranty
1. Warranty Period
One year following product delivery.
2. Warranty Coverage
TLV Euro Engineering GmbH warrants this product to the original purchaser to be
free from defective materials and workmanship. Under this warranty, the product
will be repaired or replaced at our option, without charge for parts or labor.
3. This product warranty will not apply to cosmetic defects, nor to any product whose
exterior has been damaged or defaced; nor does it apply in the following cases:
1) Malfunctions due to improper installation, use, handling, etc., by other than TLV
Euro Engineering GmbH authorized service representatives.
2) Malfunctions due to dirt, scale, rust, etc.
3) Malfunctions due to improper disassembly and reassembly, or inadequate
inspection and maintenance by other than TLV Euro Engineering GmbH
authorized service representatives.
4) Malfunctions due to disasters or forces of nature.
5) Accidents or malfunctions due to any other cause beyond the control of TLV
Euro Engineering GmbH.
4. Under no circumstances will TLV Euro Engineering GmbH be liable for
consequential economic loss damage or consequential damage to property.
* * * * * * *
For Service or Technical Assistance:
Contact your
representative or your regional
office.
Daimler-Benz-Straße 16-18, 74915 Waibstadt,
Germany
Tel: [49]-(0)7263-9150-0 Fax: [49]-(0)7263-9150-50
Star Lodge, Montpellier Drive, Cheltenham, Gloucestershire, GL50 1TY,
U.K.
Tel: [44]-(0)1242-227223 Fax: [44]-(0)1242-223077
Parc d’ Ariane 2, bât. C, 290 rue Ferdinand Perrier, 69800 Saint Priest,
France
Tel: [33]-(0)4-72482222 Fax: [33]-(0)4-72482220