BE8H series valves are designed to shut off the medium flow. The type of working
medium may make some materials unsuitable for use. Valves are designed for normal
working conditions. Working pressure is related to the maximum temperature of the
medium as shown in the table below.
Model Material
PN
-20 -10 50
100 120 150 200 250 300
350
400
Temp. (
°
C)
BE8H-16 EN-GJL-250
16 --- 16 16 16 16 14.4 12.8 11.2 9.6 --- ---
BE8H-25 EN-GJS-400-18-LT 25 --- 25 25 25 25 24.3 23 21.8 20 17.5 ---
BE8H-40 GP240GH
40 30 40 40 37.1 36.3 35.2 33.3 30.4 26.7 25.7 23.8
Maximum
Operating
Pressure
(barg)
The plant designer is responsible for selection of a valve that is suitable for
working conditions.
5. Application
・
Steam, water, air and other fluids*
(*Do not use for toxic, flammable or otherwise hazardous fluids.)
・
Industrial technologies, power industry, etc.
6. Configuration
No. Part
Name
1 Body
2 Seat
Ring
3 Bonnet
4 Stem
5 Handwheel
6 Gland
7 Plug
8 Bellows
9 Sleeve
10 Gland
Seal
11 Bonnet
Gasket
12
Bonnet Bolt/ Bonnet Nut
①
②
⑦
⑧
④
③
⑥
⑨
⑤
⑩
⑫
⑪
BE8H-16, BE8H-25
BE8H-40
⑦
7. Installation
During the installation of the Bellows Sealed Valve the following steps should be
observed:
・
Visually inspect the valve initially to ensure it is undamaged and also ensure that it
is suited to the medium and working conditions used in the plant.
・
Remove dust caps if supplied.
・
Protect the valve during installation from debris and excessive temperature
conditions.
・
Steam pipelines should be fitted in such a way as to avoid condensate collection; in
order to avoid water hammer, a steam trap should be installed.
TEG-BE8H-M-00 20 August 2013