172-65254MA-04 (A-COS-10) 22 Apr 2020
8
Installation
Install properly and DO NOT use this product outside the recommended
operating pressure, temperature and other specification ranges.
Improper use may result in such hazards as damage to the product or
malfunctions which may lead to serious accidents. Local regulations
may restrict the use of this product to below the conditions quoted.
CAUTION
Use hoisting equipment for heavy objects (weighing approximately
20 kg (44 lb) or more). Failure to do so may result in back strain or other
injury if the object should fall.
CAUTION
Take measures to prevent people from coming into direct contact with
product outlets. Failure to do so may result in burns or other injury from
the discharge of fluids.
CAUTION
Do not use excessive force when connecting threaded pipes to the
product. Over-tightening may cause breakage leading to fluid
discharge, which may cause burns or other injury.
CAUTION
Installation, inspection, maintenance, repairs, disassembly, adjustment and valve
opening/closing should be carried out only by trained maintenance personnel.
1. Blowdown
Before installing the product,
be sure to blow down all
piping thoroughly. If this is
not possible, perform a
blowdown using the bypass
valve.
Blowdown is especially
important for newly installed
piping or after the system
has been shut down for a
long period of time.
2. Removing Seal and Cap
Before installation, be sure to remove all protective seals and caps.
(Found in 3 locations, on the product inlet and outlets.)
3. Installation Angle
Make sure the product is installed on horizontal piping,
so that the arrow mark on the body matches the direction
of air flow and the adjustment section faces up.
Allowable inclination is 10 degrees in the fore-aft
direction and 15 degrees in the plane perpendicular to
the air flow line.
Open
Close
A-COS
Open