Strictly conform to local electrical safety standards and use power adapters that are 
marked with the LPS standard when installing and using this device. Otherwise, 
this device may be damaged. 

z

 

Use accessories delivered with this device. The voltage must meet input voltage 
requirements for this device. 

z

 

If this device is installed in places with unsteady voltage, ground this device to 
discharge high energy such as electrical surges in order to prevent the power supply 
from burning out. 

z

 

When this device is in use, ensure that no water or any liquid flows into the device. 
If water or liquid unexpectedly flows into the device, immediately power off the 
device and disconnect all cables (such as power cables and network cables) from 
this device.   

z

 

Do not focus strong light (such as lighted bulbs or sunlight) on this device. 
Otherwise, the service life of the image sensor may be shortened. 

z

 

If this device is installed in places where thunder and lightning frequently occur, 
ground the device nearby to discharge high energy such as thunder strikes in order 
to prevent device damage.   

 

z

 

Avoid heavy loads, intensive shakes, and soaking to prevent damages during 
transportation and storage. The warranty does not cover any device damage that is 
caused during secondary packaging and transportation after the original packaging 
is taken apart. 

z

 

Protect this device from fall-down and intensive strikes, keep the device away from 
magnetic field interference, and do not install the device in places with shaking 
surfaces or under shocks. 

z

 

Clean the device with a soft dry cloth. For stubborn dirt, dip the cloth into slight 
neutral cleanser, gently wipe the dirt with the cloth, and then dry the device. 

z

 

Do not jam the ventilation opening. Follow the installation instructions provided in 
this document when installing the device. 

z

 

Keep the device away from heat sources such as radiators, electric heaters, or other 
heat equipment. 

z

 

Keep the device away from moist, dusty, extremely hot or cold places, or places 
with strong electric radiation. 

z

 

If the device is installed outdoors, take insect- and moisture-proof measures to 
avoid circuit board corrosion that can affect monitoring. 

z

 

Remove the power plug if the device is idle for a long time. 

z

 

Before unpacking, check whether the fragile sticker is damaged. If the fragile 
sticker is damaged, contact customer services or sales personnel. The manufacturer 
shall not be held responsible for any artificial damage of the fragile sticker. 

Содержание TKIB25M1P

Страница 1: ...User manual Network LPR bullet TKIB25M1P tkhsecurity fr V 201910 01...

Страница 2: ...User Manual Network LPR Bullet TKIB25M1P EN 2...

Страница 3: ...ings are described accordingly Symbol Description It alerts you to fatal dangers which if not avoided may cause deaths or severe injuries It alerts you to moderate dangers which if not avoided may cau...

Страница 4: ...shakes and soaking to prevent damages during transportation and storage The warranty does not cover any device damage that is caused during secondary packaging and transportation after the original p...

Страница 5: ...n that is not accurate enough or product function and operation description that is slightly inconsistent with the actual product The manufacturer will update this manual according to product function...

Страница 6: ...1 2 3 Minimal distance 2 Quick Configuration 2 1 Login and Logout 2 2 Browsing Video 2 2 1 Install plugins 2 2 2 Browsing Video 1 2 3 Setting Local Network Parameters 1 2 4 Front end Configuration 1...

Страница 7: ...Armenia Uzbekistan Serbia 150 pixels for rectangular plates and 100 pixels for two row plates 2 For all other supported countries 130 pixels for rectangular plates and 70 pixels for two row plates z...

Страница 8: ...measure the vertical angle Then measure the horizontal angle You need to take the bigger of them For example if you mounting the camera on a 2 meters pole 3 meters from the road Correct vertical angl...

Страница 9: ...User Manual Network LPR Bullet TKIB25M1P EN 9 Table 1 1 Correspondence between installation height and distance h meters Minimal x meters 1 1 7 1 5 2 6 2 3 4 2 5 4 3 3 5 1 3 5 6 4 6 8...

Страница 10: ...r the IP address of the IP camera default value 192 168 0 120 in the address box and press Enter The login page is displayed as shown in Figure 2 1 Figure 2 1 Login page Step 2 Enter the user name and...

Страница 11: ...latest plugins as shown in Figure 2 2 when you log in to the web management system for the first time Figure 2 2 Download the plug ins page Step 1 Click Download and setup download and setup the plug...

Страница 12: ...ve Video 2 3 Setting Local Network Parameters Description Local network parameters include z IP protocol z IP address z Subnet mask z Default gateway z Dynamic Host Configuration Protocol DHCP z Prefe...

Страница 13: ...h of 32 bits Setting method Select a value from the drop down list box Default value IPv4 Obtain an IP address automatically The device automatically obtains the IP address from the DHCP server Settin...

Страница 14: ...ice uses the alternate DNS server to resolve domain names Setting method Enter a value manually Default value 192 168 0 2 MTU Set the maximum value of network transmission data packets Setting method...

Страница 15: ...in Figure 2 6 Figure 2 6 Front end configuration menu Step 2 Choose Sensor The front end configuration dialog box is displayed as shown in Figure 2 7 Figure 2 7 Front end configuration page Step 3 Co...

Страница 16: ...Step 4 Configure Exposure 1 Click Exposure the Exposure page is displayed as shown in Figure 2 8 Figure 2 8 Exposure page 2 Set the Meter area to centre spot 3 Set the Max Shutter to 1 1000 4 Click S...

Страница 17: ...ognition Configuration Click configuration choose License Plate Recognition at left list as shown in Figure 2 10 Figure 2 10 License Plate Recognition 2 5 List Configure List configure refers to addin...

Страница 18: ...tion Procedure Description Export 1 Click the open or save list file prompt page is displayed 2 Open or save list file according to the prompt Export the list file Import 1 Enter license plate number...

Страница 19: ...ck to search the license plate number Search the license plate number in black white list Begin time 1 click the time calendar is displayed set the begin time of white and black 2 choose to save the s...

Страница 20: ...license plate in white list recognized by camera 4 Set Not in List Action Enable the linkage actions The linkage action will be performed automatically when the license plate neither in black list no...

Страница 21: ...osition is postive such as the car position is 110 degree of picture the range from 65e to 155eis all postive direction The range from 25e to 115eis negative direction Others is undefined diretion Ste...

Страница 22: ...creenshots and upload the screenshots to FTP server Step 5 Enable Video Displaying License Plate and set Time of Duration s The snapshotted license plate number will be displayed in video image of liv...

Страница 23: ...ription Setting Time Time period of license plate recognition Setting method Click input box the calendar is displayed Choose the start time Choose the end time Country Country of license plate Settin...

Страница 24: ...ch list Parameter Description Time Time of license plate recognized by camera License Plate Number License plate Number of license plate recognized by camera License Plate Image License plate Image of...

Страница 25: ...le 3 1 Troubleshooting of the camera Problems countermeasure Photo Focus Adjust the focus on the lens Too much light Adjust the shutter speed or dim the IR Led for the night Too small License plate wi...

Страница 26: ...User Manual Network LPR Bullet TKIB25M1P EN 26 Notes...

Страница 27: ...User Manual Network LPR Bullet TKIB25M1P EN 27 Notes...

Страница 28: ...V 201910 01 153 rue Michel Carr 95100 Argenteuil FRANCE tel 33 0 1 30 76 30 30 info fr tkhsecurity com tkhsecurity fr...

Отзывы: