power consumption every 1 hour to the node of correspond Group. The maximum
interval to report its instant power consumption is 45 hours (5s*32767/3600=45hr).
Default value is 1 hour
KWH Meter Report Period:
If the setting is configured for 1 hour (set value =6), the TZ75 will report its Accu-
mulated Power Consumption (KW/h) every 1 hour to the node of correspond Group.
The maximum interval to report its Accumulated Power Consumption (KW/h) is 227.55
days (10min*32767/1440=227.55 days). Default value=1 hour
Threshold of Watt for Load Caution
This is a warning when the wattage of load over the preset threshold value, If the
setting value is 1100, when the load wattage over this value, TZ75 will send Watt
Meter Report command to the node of correspond Group. Default value=1100W.
Threshold of KWh for Load Caution
This is a warning when the KWh of load over the preset threshold value, If the setting
value is 10000, when the Accumulated Power Consumption of Relay 1 or Relay2 over
this value, TZ75 will send KWh Meter Report command to the node of correspond
Group, minimum value is 1 KWh . Default value is 0 kWh . It means no warning when
the KWH of load over the preset threshold value and not send KWH Meter Report.
Z-Wave Supported Command Class
COMMAND_CLASS SWITCH_BINARY
COMMAND_CLASS BASIC
COMMAND_GLASS MANUFACTURER SPECIFIC_V2
COMMAND_CLASS_DEVICE_RESET_LOCALLY
COMMAND_CLASS ASSOCIATION
COMMAND_CLASS METER_V3
COMMAND_CLASS CONFIGURATION
COMMAND_CLASS SWITGH_ MULTILEVEL_V3
Wrong connection of
NO1 and NO2 to the
motor
Swap the NO1 NO2
connection
The shutter move
direction is reverse
Symptom
Cause of Failure
Recommendation
The TZ75 not working
and LED off
1. The TZ75 is not
connect to the Main
power
2. The TZ75 break down
1. Check power connections
2. Don't open up the TZ75
and send it for repair.
TZ75 LED light work fine
But can not control
1. No association setting
2. Same frequency
interference
1. Carry out association
2. Wait for a while to retry
Operating Voltage
Maximum Load
110
240VAC
Resistive Load 1100W/600W(EU/US) max
Minimum 40m in door ,70m outdoor line of sight
0
40
℃
868.4MHz(EU) 908.42MHz(US) 921.42MHz(AUS)
~
℃~
Range
Operating temperature
Frequency Range
Specifications are subject to change and improvement without notice.
Specification
Troubleshooting
-7-
-6-