The group identifier is "Group 1".
Association group info report command class
Profile: General lifeline (Profile MSB=0,Profile LSB=1)
Association group name report command class
Group 1: lifeline
LED Indication
To distinguish what mode the TZ75 is in, view from the LED for identification.No matter
up or down, close or open, Led will flash every two seconds while Motor activate.
Under normal operation, when the TZ75 has not been allocated a node ID,the LED
flashes on and off alternately at 1-second intervals. By pressing S1,S2 0r Include button,
it will stop flashing temporary. However, after disconnect and reconnect the TZ75,
the LED will flash on and off alternately at
.
When overload state occurs, the TZ75 is disabled of which LED flashes on and off
alternately at 0.5 second intervals. Overload state can be cleared by disconnect and
reconnect the TZ75 to the main power.
Installation an operation
1. Put the in wall TZ75 into a wall box and connect the AC power wire L, N to TZ75
connector L, N.
2. Connect the wall switch to the TZ75 .
3. lt is important to carry out a shutter calibration process before you control the
shutter to move. Press inclusion button over 3 seconds and release before the 6th
second, the roller shutter controller will start the shutter calibration process. The
process is composed of three continue stages. The shutter move to the BOTTOM
in first stage, and move to the TOP in second stage, and move to the BOTTOM
again in
1-second intervals
third stage. Then TZ75 will know the total range of UP and DOWN.
4. During the shutter calibration process, any emergencies happen you can press and
release the include button to stop the process.
5. If user found the direction is reverse, this may because the wrong connection of
NO1 and NO2 to the motor, please change NO1 and NO2 connection and execute
calibration process again.
6. To manually switch up and down of the shutter, simply press S1or S2 .
7. TZ75 built in meter function and can read the Watt, KWh, V(Voltage), I(Current)
PF(Power Factor) of the load by using Z-Wave command class.
8. TZ75 have overload protection function, and can help to prevent short circuit
caused by load.
Configuration
Parameter
Function
Size
(Byte)
Value
Unit
Default
Description
1
2
3
4
2
2
2
720
6
1100
0
0x01-
0x7FFF
10-1100
0-10000
Watt Meter
Report period
KWH Meter
Report period
Threshold of
Watt for load
caution
Threshold of
KWH for load
caution
5s
5*720s=3600s
=1 hour
6*1min=1 hour
10min
1 Watt
Kwh
2
0x01-
0x7FFF
Z-Wave Configuration
Watt Meter Report Period:
If the setting is configured for 1 hour (set value =720), the TZ75 will report its instant
-5-
-4-