TJERNLUND IN-FORCER PAI-10 Скачать руководство пользователя страница 18

17

1.) Follow troubleshooting guide to determine defective component.  If unable to determine faulty component, contact your 

Tjernlund distributor or Tjernlund Products Technical Customer Service Department at 1-800-255-4208 for troubleshooting 
assistance.

2.) After the faulty component is determined, return it to your Tjernlund distributor for replacement.  Please include IN-FORCER date 

code component was taken from.  The date code is located on the Electrical Box coverplate.  If the date code is older than 18 
months you will need to provide a copy of the original installation receipt to your distributor.  Credit or replacement will only be 
issued to a Tjernlund distributor after the defective part has been returned prepaid to Tjernlund.

COVERED PARTS

Motor       

Proving Switch                   Relay        

Indicator Light       

Blower Wheel

WHAT IS NOT COVERED

Product installed contrary to our installation instructions
Product that has been altered, neglected or misused
Product that has been wired incorrectly
Product that has been damaged by a malfunctioning or mistuned burner
Any freight charges related to the return of the defective part
Any labor charges related to evaluating and replacing the defective part

IN-FORCER REPLACEMENT PARTS LIST

MOTOR KIT

950-3022

PAI-1 WHEEL KIT

950-0451

PAI-2 WHEEL KIT

950-0457

FAN PROVER KIT

950-0452

RELAY KIT

950-1040

24V INDICATOR LIGHT 

950-0455

115V INDICATOR LIGHT KIT

950-0456

IN-FORCER ISOMETRIC PARTS BREAKDOWN

TJERNLUND LIMITED ONE YEAR WARRANTY

Tjernlund Products, Inc. warrants to the original purchaser of this product that the product will be free from defects due to faulty material or workmanship for a period of  (1) year from the date of orig-
inal purchase or delivery to the original purchaser, whichever is earlier.  Remedies under this warranty are limited to repairing or replacing, at our option, any product which shall, within the above stat-
ed warranty period, be returned to Tjernlund Products, Inc. at the address listed below, postage prepaid.  THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THE DESCRIPTION ON THE
FACE HEREOF, AND TJERNLUND PRODUCTS, INC. EXPRESSLY DISCLAIMS LIABILITY FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES ARISING FROM THE USE OF THIS PRODUCT.
THIS WARRANTY IS IN LIEU OF ALL OTHER EXPRESS WARRANTIES AND NO AGENT IS AUTHORIZED TO ASSUME FOR US ANY LIABILITY ADDITIONAL TO THOSE SET FORTH IN THIS
LIMITED WARRANTY.  IMPLIED WARRANTIES ARE LIMITED TO THE STATED DURATION OF THIS LIMITED WARRANTY.  Some states do not allow limitation on how long an implied warranty
lasts, so that limitation may may not apply to you.  In addition, some states do not allow the exclusion or limitation of incidental or consequential damages, so that above limitation or exclusion may
not apply to you.  This warranty gives you specific legal rights and you may also have other rights which may vary from state to state.  Send all inquires or products requiring warranty work to Tjernlund
Products, Inc. 1601 9th Street, White Bear Lake, MN 55110-6794 Phone (651) 426-2993 • Fax (651) 426-9547 or email us at [email protected].

NOTE: 

For pull-down servicing feature of
IN-FORCER, remove six (6)
screws from bottom front and
sides of IN-FORCER while holding
blower assembly firmly.  Carefully
slide blower assembly down until
stops hold in place.  

Содержание IN-FORCER PAI-10

Страница 1: ...Inc All rights reserved P N 8504038 THIS DEVICE MUST BE INSTALLED BY A QUALIFIED PERSON READ INSTRUCTIONS CAREFULLY PRIOR TO INSTALLATION AND OPERATION OF THE AIR INTAKE SYSTEM REV A 5 01 TJERNLUND PR...

Страница 2: ...C Hole Template 18 IN FORCERTM is a trademark of Tjernlund Products Inc for IN FORCER air intakes DESCRIPTION The IN FORCER combustion fans are mechanical air intake fans designed and Listed for use w...

Страница 3: ...t additional combustion air will eliminate carbon monoxide spillage into the home SAFETY INSPECTION OF A PREVIOUSLY USED OIL APPLIANCE Perform prior to IN FORCER installation The following procedure i...

Страница 4: ...ts from the National Fuel Gas Code ANSI Z223 1 NFPA 54 Appendix H IN FORCER TERMINOLOGY INTAKE ELBOW TERMINATION CLEARANCES The IN FORCER has been Listed in accordance with the 1990 BOCA national Mech...

Страница 5: ...diameter PVC pipe lengths from 2 to 20 feet The left hand column has outlet 6 diameter pipe lengths from 0 to 20 feet Pipe lengths must be calculated in equivalent feet See Diagram H Page 6 With corr...

Страница 6: ...ding etc following the template outline for the pipe See Diagram D 5 Knock out material exposing hole through the wall TRUSS MOUNTING If IN FORCER will be mounted on a floor truss instead of a joist f...

Страница 7: ...traight pipe Each 90 degree elbow of 6 metal vent pipe is equal to 10 feet of straight pipe each 45 degree elbow is equal to 5 feet of straight pipe For an example of how to calculate equivalent feet...

Страница 8: ...quivalent lengths must be calculated See Diagram H Page 6 The discharge should terminate three feet from a barometric draft control or air intake of an appliance If this is not possible terminate on s...

Страница 9: ...hat the electrical interlock of the IN FORCER is always done at the final signal which would normally start the burner motor All thermostats zones limits and circula tors are to be wired as normally d...

Страница 10: ...trols as nor mally done when conventional venting before continuing Disconnect power from the appliance before attempting to interlock IN FORCER The instructions below assume that the IN FORCER and SS...

Страница 11: ...FORCER INTERLOCKED ON 24V GAS APPLIANCES As the thermostat aquastat senses a call for heat the internal switch of the the thermostat aquastat will close The switch closure sends current through the in...

Страница 12: ...rlock IN FORCER Step 1 Cut wire that is factory installed to the TH or MV HOT terminal of gas valve Step 2 Connect YELLOW wire from IN FORCER control cable to TH or MV HOT of gas valve Step 3 Connect...

Страница 13: ...assume that the IN FORCER and Power Venter are installed at the same time Step 1 Remove wire connected to the MV HOT terminal on appliance electronic ignition module Step 2 Reconnect wire removed in s...

Страница 14: ...steps 3 6 3 Close all doors and windows of the building If heating equipment is installed in a utility room or closet close the entrance door to the room Close fireplace dampers 4 Turn on all equipme...

Страница 15: ...Products Inc Technical Customer Service Department at 1 800 255 4208 Wiring not correct No No SYMPTOM 1 IN FORCER PAI O OIL SERIES RUNS BUT BURNER DOES NOT FIRE SYMPTOM 2 IN FORCER PAI O OIL SERIES W...

Страница 16: ...ppliance calling for heat and the IN FORCER running check for voltage across YELLOW and RED control cable leads Result Measure 24 volts Step 1 Recheck all wiring per the installation instructions Step...

Страница 17: ...r under one year All receipts should include the date code of the IN FORCER to ensure that the defective component corresponds with the complete unit This will help preclude possible credit refusal 11...

Страница 18: ...ser of this product that the product will be free from defects due to faulty material or workmanship for a period of 1 year from the date of orig inal purchase or delivery to the original purchaser wh...

Страница 19: ...18...

Отзывы: