background image

26

Summer Bypass Setup

Use to adjust value up or 
down.

Enter key.

Extract

Supply

Use the Supply and Extract buttons to select which threshold is to 
be adjusted.  Supply represents from atmosphere air temperature; 
Extract represents from dwelling air temperature.

Tap button[4] to enable / disable SUMMERboost.
Unfilled icon (shown) represents disabled.

Passcode Enable / Disable

Tap Enter key 
to edit state.

Use to enable / disable 
Passcode.

- - - - indicates Passcode is disabled. 
3 3 3 3 indicates Passcode is enabled.

Содержание aura-t

Страница 1: ...aura t TP536 EU aura t SMART TP736 EU aura t SMART AR m h for HRV3QAR TP737 EU auraSMART app EN ventilation systems HRV controllers Product Manual ...

Страница 2: ...be connected using the communication cable provided this can be extended up to 30m Control Communication cable Unshielded 4 Core 18 24AWG Stranded Tinned Copper 5 Control communication cables should not be placed within 50mm or on the same metal cable tray as any 230V lighting or power cables 6 Ensure all cable glands are fully tightened Important environmental information about this product This ...

Страница 3: ...can be used by children aged from 8 years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concern ing use of the appliance in a safe way and understand the hazards involved 10 Children should be supervised to ensure that they do not play with the appliance 11 To avoid damaging the touc...

Страница 4: ...T WiFiTimers 11 auraSMART User Guide HomeWiFi Internet connection Option 1 12 WiFi Direct Option 2 14 auraSMART app screens 15 Run Mode 15 Boost Control 15 HumidityThreshold Control 15 Fan Commissioning 15 Summer Bypass 15 Control Switch settings 15 Installation Location 16 Fixing 16 Wiring 17 Fan Commission 18 Cloning 19 Saving Fan Speeds to the aura t 19 Timer Setup 20 Timer Defaults 23 Controll...

Страница 5: ...remotely from the unit The aura t SMART units can also connect and to the Titon auraSMART app using WiFi either directly or using a WiFi network and can be used to commission and control the HRV Packaging Contents Inspect the unit when taking delivery Check the unit for damage and that all accessories have been supplied Package supplied with 1 x aura t controller 1 x 3m aura t communication cable ...

Страница 6: ...rolled Boost Inhibit Boost Inhibit is used to prevent the HRV s speed increasing Boost Inhibit is used in conjunction with a Timer event Status Icons The aura t displays icons to indicates modes of operation in Real time App Store Speed Selection Display The unit speed can be manually selected via the on screen 1 2 3 4 buttons icons which are also used to display any automatically selected speed 2...

Страница 7: ... the touchscreen Tab Function Monitor Control Fan Commission Timer Setup Name Run Mode Timer Mode Setup Mode Description Displays Fan Speed Time Day and Status Gives access to Fan Speed Setup Gives access to Timer Run Pause and Timer Setup Gives access to Time Day RH threshold Overrun Timers Summer Bypass Passcode settings Filter Reset Switch Setup in a Sub Menu If passcode is enabled enter 3333 t...

Страница 8: ...lso shown on this screen in 24 hour format along with the days of the week the current day is ringed Status Icons If the fan speed is being controlled by an external switch a sensor or the timer this is indicated by an icon beneath the speed selection buttons being visible The icons are as follows An external switch is active and is controlling a function of the unit The timer is active and is kee...

Страница 9: ...the property and stale hot air is extracted Press Hold the 4 button to cancel SUMMERboost The Boost Overrun timer is active and is holding the HRV at Speed 3 this follows an external Boost switch being deactivated or if the internal Humidity sensor has put the unit into Boost and the Humidity has reduced below the set point The padlock icon adjacent to the Speed 3 button and accompanying the timer...

Страница 10: ... buttons displayed on screen have the following functions Tap the Play Pause button to toggle between play and pause Press and Hold to pause timers indefinitely The Run arrow indicates the timer is currently active and will be used to switch the HRV in and out of Speed 1 The Pause and Hour Glass symbols indicate the Timer is temporarily paused Timer will restart 8 hours after being invoked The Pau...

Страница 11: ...f Boost Inhibit is in operation auraSMART WiFi Timers 1 The auraSMART App has a seven day eight events per day timer The timer is used to automatically change the HRV speed to any of the speeds at programmed times 2 An additional function of the timer is that when it activates Speeds 1 or 2 there is an option to engage Boost Inhibit 3 If the timer is being controlled by the app the timer screen be...

Страница 12: ... and conditions You will receive an e mail with a link to activate your account you will not be able to access account facilities until completing the activation process Log in to your new account using the account name and password that you just created 5 In your phone WiFi settings ensure your phone is connected to the same WiFi router as the aura t will be connected not a 3G 4G mobile connectio...

Страница 13: ...ult displayed on the label in the WiFi module c Press then using the arrow buttons select to make a WiFi internet connection pressing to select d Tap to return to Run screen e The WiFi symbol will flash to confirm the aura t is searching for a connection f In the app check the Device is ready for internet connection and click NEXT g In the app click OK as shown Once paired the aura t will display ...

Страница 14: ...on is to search for a WiFi internet router network connection ii icon is to search for a WiFi Direct connection see section 2 iii icon resets the aura t WiFi module passcode to default displayed on the label in the WiFi module b Press then using the arrow buttons select to create a WiFi direct hotspot pressing to select c The display screen will show 4 Connect your phone to the aura t SMART WiFi d...

Страница 15: ...dity Sensor s trigger point is variable from 30 RH to 100 RH Fan Commissioning When installing any HRV unit it s important to get the air flow correct as per design specifications The Fan Commissioning section allows installers to adjust the air flow accordingly Ideal for maintenance and quick and easy commissioning Passcode 3333 Summer Bypass During summer months it s important to put your HRV un...

Страница 16: ... control cable will reach Fixing 1 Un clip the front of the aura t case from the Back Plate 2 Thread the control cable through the hole in the Back Plate 3 Fix Back Plate 4 Connect the communication cable see Wiring section 5 Clip the front of aura t to the Back Plate Connection to HRV 60 Fixing Holes Wiring Access Hole ...

Страница 17: ... cable may be supplied fitted with a plug in connector for connection to the HRV if the HRV does not have a socket remove the plug and use the wiring diagrams below 12V A B 0V MVHR 12V A B 0V Connection to HRV Connection to aura t ...

Страница 18: ...row keys to adjust the fan speed The fan will respond in real time to the adjustment being made 4 Repeat the above for all fan speeds requiring adjustment 5 When all of the fan speeds are correct tap the Save button to store all the fan speed settings to memory and exit back to Run Mode Additionally Speed 1 can be set to Zero Off This is achieved by setting Speed 1 to 14 0 72 m hr with TP737 then ...

Страница 19: ...nter button the arrow buttons will be illuminated and the speeds could be adjusted as detailed in Commissioning or simply written to the HRV by tapping the Save button Saving Fan Speeds to the aura t Extract Supply To save the current fan speed to the aura t press and hold the Supply or Extract buttons The copy icon will be illuminated and when save is tapped the fan speeds will be saved to the au...

Страница 20: ...n Tap the Timer Mode tab to enter the Timer Mode menu 1 Tap the Timer Setup Key to commence setup 2 A ring around the day selected will blink Change the day that the timers are to be edited by using the Arrow Keys 3 Tap the Enter Key to start editing timers for that day ...

Страница 21: ...ed event will highlight 2 Use the fan keys to select either the time the HRV will switch into Speed 1 or Speed 2 3 Speed 1 key toggles between selecting Speed 1 and selecting Speed 1 with Boost Inhibit indicated by Padlock Icon 4 The selected time will flash use the arrow keys to adjust in 5 minute increments 5 Select the other events 1 4 to edit check their times and function as required 6 When a...

Страница 22: ...e to exit to Run Mode 4 When copying the just edited day is ringed and the following day has a flashing ring Tap the Enter key to select this day solid ring indicates selection or use the arrow keys to choose days and the Enter key to select deselect 5 When all required day s have been selected tap the Save key to complete the copy and return to step 1 Day Selection Screen 6 Repeat day event and t...

Страница 23: ...peed 1 and Speed 2 are identical are ignored by the timer Days Event Speed 1 Speed 2 00 00 06 30 08 30 12 00 13 30 18 00 22 30 00 00 00 00 07 30 09 30 12 00 14 00 18 00 22 30 00 00 Press Hold the Timer Tab to load reload the above default setting for the timer this action also opens Timer Setup ...

Страница 24: ...g Setting Selection Arrow keys are used to select a setting the setting will flash Tapping the Enter key will allow the setting to edited Tap the Exit button to return to Run Mode Setting Editing Arrow keys are used to change setting value Tapping the Enter key whist editing will save and move to the next setting in the list The order in which editable settings are displayed is as follows 1 Time 2...

Страница 25: ...nection to WiFi Direct 9 Filter Reset If a filter change is required the reset ring will be flashing Tap the Enter key to reset or the Exit key If a filter change is not due but the filter timer requires resetting press the Enter key twice Tap Exit key to return to Run Mode aura t with auraSMART WiFi icon definitions Full Connection Connected to Local network Internet or Server unavailable Local n...

Страница 26: ... be adjusted Supply represents from atmosphere air temperature Extract represents from dwelling air temperature Tap button 4 to enable disable SUMMERboost Unfilled icon shown represents disabled Passcode Enable Disable Tap Enter key to edit state Use to enable disable Passcode indicates Passcode is disabled 3 3 3 3 indicates Passcode is enabled ...

Страница 27: ... Setup Mode tab to enter the Switch Setup Mode menu Switch Setup menu active All switch inputs to the HRV unit S1 S2 S3 LS1 LS2 can be assigned any of the following functions Kitchen Boost Speed 3 Wet Room Boost Speed 3 Speed 1 Setback SUMMERboost disable Speed 4 Off Normally Open Off Normally Closed Manual Summer Bypass If Passcode is enabled access to the Switch Setup Menu is only available from...

Страница 28: ...able Configurable Item Range Default Configured Additional information Min Max Time Any Time 00 00 24 hour clock Day of Week 1 7 1 Two groups five week days two weekend days Boost Overrun Kitchen 0 mins 60 mins 15 mins Wet Room 0 mins 60 mins 15 mins Boost Overrun timers are set independently for Kitchen and Wet Room inputs Boost Overrun timers must be set greater than zero for any momentary switc...

Страница 29: ...y a latching switch if fitted Switch Inputs SW1 Kitchen Boost SW2 Wet Room Boost SW3 SUMMERboost Disable Switch options are Kitchen Boost Wet Room Boost Speed 1 Speed 4 SUMMERboost disable OFF normally open OFF normally closed Manual Summer Bypass When configured as Kitchen or Wet room Boost the switch will use the associated Boost overrun and delay times for that room Live Switch Inputs LS1 Kitch...

Страница 30: ...tmosphere side of the heat cell drops below the Frost Protection Threshold When operating in Reduce Mode the speed of the Supply Fan is gradually reduced when the temperature drops below the threshold At 4 C below the threshold it is stopped Duct Heater Enable Disable Enabled Disabled Disabled Duct Heater Mode Frost User Frost Duct Heater Threshold 4 C 16 C 4 C Duct Heater Hysteresis 1 C 10 C 1 C ...

Страница 31: ...onmental parameter they are measuring Below their lower threshold they have no effect on the ventilation rate once the lower threshold is exceeded the fan speeds proportionally increase from Speed 2 Continuous until the upper threshold is reached when the fans will be running at Speed 3 Boost In addition to the RH and CO2 sensor detailed above Air Quality and Temperature Room Sensors may be fitted...

Страница 32: ...Fax 44 0 1206 543126 Email ventsales titon co uk Web www titon com 2021 TITON DO 5745 Iss 04 In the event of any queries please contact the system installer Ensure this booklet is passed to the householder once installation commissioning of the ventilation system is complete This Product Manual must be kept in the Home Information Pack ...

Отзывы: