3  

2.4 Product Installation

   

Desktop Installation 

Step 1: 

Set the bottom of the switch up on a flat and stable desktop;   

Step 2: 

Paste four cushions in the corresponding concave places at the bottom; 

Step 3: 

Turn over the switch and place it face up on the workbench. 

 

Figure 2-1 

Desktop Installation 

Magnet Installation 

Step 1:

 Attract 4 magnets into the corresponding round grooves on the bottom at 

each corner of the switch’s housing;   

Step  2:

  Use  screws  to  secure  the  magnets  to  the  switch’s  housing,  shown  as 

Figure 2-2 (a); 

Step  3:

  Press  the  switch  (installed  with  magnets)  in  a  proper  way  on  a  stable 

surface you select, shown as Figure 2-2 (b). When installing, be careful with your 
fingers. 

 

 

 

Figure 2-2 

Magnet Installation 

Note: 

l

 

Select  the  installation  surface  carefully.  If  the  surface  is  not  proper,  the 
reliability of this installation will be influenced. 

l

 

Too  high  installation  position  or  vibration  might  cause  a  fall  leading  to 

Содержание TNDS-9000P

Страница 1: ... This Install Guide is for TNDS 9000P Preface Chapter 1 Introduction Introduction to switch features and its physical description Chapter 2 Installation Introduction to the installation methods and consideration Chapter 3 Hardware Connection Introduction to the connection between the switch and other devices and considerations Technical Support Helpline Manufacturer TitanNetworx LTD Address 18th f...

Страница 2: ...ty allow you to quickly detect and correct problems on the network It also applies Power over Ethernet PoE power supply up to 30W output power per port which can solve the problems resulting from wiring complexities high cost and maintenance difficulties of Wireless LAN APs IP Phones and IP Cameras 1 2 Package Contents Open the package and verify the following items carefully If any of the listed ...

Страница 3: ...details shown as Table 1 1 Table 1 1 PoE capable RJ45 Ports Tips Ethernet cables Pair 1 and 2 Pair 3 and 6 are employed for PoE power supply You re recommended to use Cat 5 or higher UTP STP cables When you use Cat 5e and Cat 6 twisted cables the PoE power supply distance is up to 150 meters TNDS 9000P PoE capable Ports 1 8 l IEEE 802 3af compliant and IEEE 802 3at compatible l Up to 8 IEEE 802 3a...

Страница 4: ...ty PoE ports will be disconnected from power supply one by one unless the PoE power consumption returns to normal the PoE MAX turns off Note Among PoE ports on the switch power priority is determined by the port number with lower numbered ports having higher priority Off PoE consumption is proper Link Act RJ45 with LEDs Orange Solid Proper network connection on the corresponding RJ45 port Blinking...

Страница 5: ...ttach the switch to a fixed object against theft 2 Grounding Terminal Use a wire to connect the terminal to the ground for lightning protection For details please refer to 2 5 Connect to Protective Grounding Cable 3 Power Input Jack Please plug the power adapter to this input jack to supply power for the switch Note Please use the provided power supply Power Input 100 240V AC 50 60Hz Power Output ...

Страница 6: ...clean it by the waterish cloth and never use any other liquid cleaning method l Keep the switch away from nearest source of high voltage such as power lines electric lamps grids etc Note There is a TN unpacking seal on one of the screws If you want the local reseller maintain your device the seal should be kept unbroken Before you open the device s housing please contact the local reseller to get ...

Страница 7: ...utlet has a good contact with the ground l Keep a reasonable cabling system to avoid induced lightning l Use the signal SPD Surge Protective Device when wiring outdoor Installation Site When installing the device on a rack or a flat workbench please note the following items l Make sure that the rack or workbench is sturdy enough to support the switch and well grounded l Make sure that the switch h...

Страница 8: ...ing round grooves on the bottom at each corner of the switch s housing Step 2 Use screws to secure the magnets to the switch s housing shown as Figure 2 2 a Step 3 Press the switch installed with magnets in a proper way on a stable surface you select shown as Figure 2 2 b When installing be careful with your fingers Figure 2 2 Magnet Installation Note l Select the installation surface carefully If...

Страница 9: ...pen Wall Installation Step 1 Punch 2 holes with a diameter of 5mm on the wall The distance between the 2 holes is 110mm and the line through them should keep horizontal as illustrated in Figure 2 3 Step 2 Install a conductor pipe inside the board hole and flush the edge of the conductor pipe with the wall surface Step 3 Screw the bolts into the conductor pipe Distance between the inside surface of...

Страница 10: ...switch s grounding cable should be connected to the engineering land in the IT room Water hoses and lightning rods are not proper for grounding Without Grounding Bar 1 With mud land nearby and allowed to bury grounding bar Bury an angle iron or steel pipe 0 5m into the mud land The protective grounding cable should be welded to the angle iron or steel pipe and the welding point should be embalmed ...

Страница 11: ...C power supply transformer is well grounded Figure 2 6 Install with the grounded power cord Chapter 3 Hardware Connection Connection Procedures Check Step 1 Use an Ethernet cable to connect one upstream network device such as another switch or a router to the Uplink port on the switch shown as Figure 3 1 Figure 3 1 Connect an upstream network device Step 2 Use other Ethernet cables to connect down...

Страница 12: ...pter provided in the product package to supply power for the switch shown as Figure 3 3 Figure 3 3 Connect to power supply Step 4 After powered up the switch begins auto initialization Check the LED indicators and they will respond as follows l All the functional LEDs will flash momentarily for one second and then be off which represents a resetting of the system l The POWER LED indicator is lit ...

Страница 13: ...itch 127 5W maximum l Total power of the PoE power supply 121 22W maximum ports 1 8 output power per port 30W maximum l 51VDC 2 5A power output plug is localized to country of sale LEDs POWER LED PoE LED PoE MAX LED Link Act LED Network Medium Cat 5 100m or Cat 5 higher UTP STP cables 150m recommended Operating Temperature 10 C 45 C Storage Temperature 40 C 70 C Operating Humidity 10 90 RH non con...

Страница 14: ...adiofrequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense FCC Caution Any changes or modifications not expressly approved by the part...

Страница 15: ... 1 0 ...