TA750
(0001)
57
/
98
Fault
Cause
Remedy
Strap tension isn’t enough.
Strap tension not set correctly.
Check value set on the operator
panel and correct, if required.
Li-Ion battery insufficiently
charged.
Check charge of Li-Ion battery and
recharge it.
Tension motor
(505)
, gear unit
(90)
or circuit board
(120)
defective or worn.
Check tension motor
(505)
, gear
unit
(90)
and circuit board
(120)
for
damage (visual inspection),
contact
TITAN service dept.
Plastic strap tears when being
tensioned.
Strap tension setting too high.
Correct strap tension value set on
the operator panel downward.
Edges of packing item too
sharp.
If sharp packing item edges exist,
use an edge saver.
Use of inappropriate plastic
strap.
Use appropriate plastic strap, ask
your TITAN
– Adviser for advice.
Feed wheel slips trough.
Feed wheel
(91)
and/or gripper
plate
(6)
were polluted. Gearing
is worn or defective.
Clean feed wheel
(91)
and/or
gripper plate
(6)
. Check gearing,
replace when damage becomes
visible.
Strap tension setting too high.
Correct strap tension value set on
the operator panel if necessary.
Use of inappropriate plastic
strap.
Use appropriate plastic strap, ask
your TITAN
– Adviser for advice.
Seizing signs on plastic strap.
Ambient temperature too high.
Reduce the ambient temperature.
Gap between feed wheel
(91)
and gripper plate
(6)
is too
small.
Increase the gap between feed
wheel
(91)
and gripper plate
(6)
, ask
your TITAN
– Adviser for advice.
Use of inappropriate plastic
strap.
Use appropriate plastic strap, ask
your TITAN
– Adviser for advice.
The plastic strap tensioned is
bent on its side, it is not proper
within the strap guidance
’s; the
seal is not in the centre.
Strap tension not set correctly.
Check value set on the operator
panel and correct, if required.
Strap dimension and strap
guidance’s does not fit together.
Check strap dimension and strap
guidance
’s, they must fit together, if
required replace the strap
guidance’s or use other strap.
Use of inappropriate plastic
strap.
Use appropriate plastic strap, ask
your TITAN
– Adviser for advice.
During the tensioning operation
the tool moves forward.
Strap tension not set correctly.
Check value set on the operator
panel and correct, if required.
Gripper plate
(6)
were polluted,
gearing is worn or defective.
Clean gripper plate
(6)
, check
gearing, replace when damage
becomes visible.
Use of inappropriate plastic
strap.
Use appropriate plastic strap, ask
your TITAN
– Adviser for advice.
After the tensioning operation
the tool moves backward and
the plastic strap loosens.
Free wheel
(81)
or drawn cup
roller
(84)
, and/or plastic strap
holding unit were defective.
Contact TITAN
– Service.
H TA750 EU 46/17
Содержание TA750
Страница 31: ...TA750 0001 31 98 12 Konformitätserklärung H TA750 EU 46 17 ...
Страница 59: ...TA750 0001 59 98 12 Declaration of conformity of the machine H TA750 EU 46 17 ...
Страница 88: ...TA750 0001 88 98 12 Déclaration CE de conformité des machines H TA750 EU 46 17 ...
Страница 90: ...TA750 0001 90 98 TA750 13 Explosionszeichnungen Exploded drawings Vue éclatée H TA750 EU 32 18 ...
Страница 91: ...TA750 0001 91 98 H TA750 EU 46 17 TA750 ...