TA750
(0001)
46
/
98
a.)
Press and hold
the
SET
button for 3 seconds
to choose
one of the operating modes.
The operating mode which is set
starts flashing.
b.) Afterwards press the SET button as
long as
the
desired operation mode starts
flashing
.
When you
release
the
SET button
, the
operation mode you set
will stop blinking
after about 3 seconds, the set operation mode
is stored
.
8. Settings
The
setting only works when being enabled!
(press push-button 1 for a moment / LED signal lamp must be bright)
8.1. Operating modes
The
TA750 can be operated
in
three different operating modes
:
Automatic
AUT
Semi-automatic
SEM
Manual
MAN
8.2. Tensioning force / welding time
Press and hold the adjust button for 3 seconds to adjust
the tensioning force or welding time
until the number above
the adjust button flashes.
Now you can
adjust
the desired
tensioning force / welding
time by pushing the adjust button repeatedly until
the
desired value is displayed
.
1 = low tensioning force / welding time
9 = high tensioning force / welding time
When you release the adjust button the set value will stop
blinking after about three seconds and the value you set will be
stored.
Welding time
Tensioning
force
H TA750 EU 46/17
Содержание TA750
Страница 31: ...TA750 0001 31 98 12 Konformitätserklärung H TA750 EU 46 17 ...
Страница 59: ...TA750 0001 59 98 12 Declaration of conformity of the machine H TA750 EU 46 17 ...
Страница 88: ...TA750 0001 88 98 12 Déclaration CE de conformité des machines H TA750 EU 46 17 ...
Страница 90: ...TA750 0001 90 98 TA750 13 Explosionszeichnungen Exploded drawings Vue éclatée H TA750 EU 32 18 ...
Страница 91: ...TA750 0001 91 98 H TA750 EU 46 17 TA750 ...