17
PROGRAMMING GUIDE
The following menu selections are programmable in the ProPAC-3 Program Mode, Version 3.01
MENU SECTION
ADMINISTRATION SECTION
GRAND ADDITIVE TOTAL
GRAND PRODUCT TOTAL
PERMISSIVE INPUT
(Hardware or software)
AUTHORIZE (hardware or software)
FLOW SWITCH INPUT
CONFIRMATION PULSE OUTPUT
CONFIRMATION PULSE WIDTH
SCALED PULSE WIDTH
SCALED PULSE AMOUNT
PERMISSED PERMISSIVE
PUMP START
TEST INJECTIONS
TEST INJECTION ADD IN
FRONT PANEL LOCKOUT
PASSWORD
END OF LOAD COMPENSATION
ADDITIVE PRE-LOAD
ADDITIVE UNITS
CALIBRATION MODE
LOAD TIMEOUT
ALARM SECTION
PUSHBUTTON CLEARS ALARMS
ADDITIVE FLOW PROBLEM
NO ADDITIVE PULSE
NO PRODUCT PULSE
LINE FLUSH FAILED
RANGE / PROGRAM
SELECTION
0.0000 - 9999999999.9999
0.00 - 99999999999.99
1,2, or 3
Enabled / Disabled
Enabled / Disabled
Scaled Pulse/End-of-Batch
1-32,000 mS
1-32,000 mS
10-32,000 cc's
Enabled/Disabled
Enabled/Disabled
Enabled / Disabled
Enabled / Disabled
Enabled / Disabled
0-99,999
Enabled/Disabled
Enabled/Disabled
Gallon/Liter
Enabled / Disabled
1-900
Enabled / Disabled
Enabled / Disabled
Enabled / Disabled
Enabled / Disabled
Enabled / Disabled
RECOMMENDED PROGRAM
SETTING
none
none
enter the number of channels used
3 channels available for rate selection
normally not used
Output typically wired to load preset
Used with Confirmation Pulse only
Used with Scaled Pulse only
Used with Scaled Pulse only
As desired, if authorize is enabled
When using pump start feature
Enabled
Enabled
Enabled- when using Password
Enter number when Lockout Enabled
Used with Additive Quantity Alarm
Typically used with product line flush
Gallon for USA
Enabled
180 sec. for 3 min load timeout
Enabled
Enabled
Enabled
Requires use of flow switch input
Used only when using line flush feature
Содержание ProPAC-3
Страница 39: ...39 ...