16
CHANNEL SECTION
Ch1 Product Total
- Provides product total in gallons, for Channel 1.
Note:
If using a 40:1 product pulse, the total provides a count of the injection requests, not gallons, when
the Product K-Factor is programmed to 1.00. However, if the Product K-Factor is set to 0.025 and the
Product Set is programmed 40, the unit will increment by 40 gallons for each 40:1 product pulse input
(injection request). When using a 40:1 product pulse, this is the preferred method of accounting for the
product treated. This is very useful when using the Comm-link monitoring or ticketing systems for
documenting additive and product throughput.
Ch1 Product K-Factor
- Defined as product pulses per gallon. Provides the user the ability inject
additive via a wide range of product pulse inputs. Range 0.0001-9999.9999.
Note 1
: When a 40:1 pulse is provided, 0.025 is programmed for the Product K-Factor, and the Product Set
is programmed 40, the Channel Product Total will increment by 40 gallons on each injection request. When
the a 20:1 pulse is provided, 0.05 is programmed for the Product K-Factor, and the Product Set is
programmed 20, the Channel Product Total will increment by 20 gallons, on each injection request. When
using a 1:1 pulse or a turbine meter pulse input, provided the program values are correct, the Channel
Product Total will increment 1 gallon for each gallon of product loaded.
Note 2
: It is recommended to use a 1:1 product pulse or turbine meter pulse as the ProPAC-3 product input
pulse so accurate product loads may be documented and accounted for.
Ch. 1 Product Set
- Defined as product units (gallons or Liters) per injection request. Used to
designate the volume of product units (gallons or Liters) to be counted, prior to initiating an injection
request. Typical injections are made every 20 or 40 gallons of product. Program range 1-9999 gallons.
The following displays the relationship between the various product program menu selections:
Ch1 Additive Total
- Reflects the total additive volume, in gallons, dispensed through the
ProPAC-3 flow meter for Channel 1. If Channel 1 is the only channel used, then the Channel 1 Total should
match the Grand Additive Total. Programmable 0.0000-999999999.9999.
Ch1 Additive K-Factor
- The additive K-Factor is determined via a calibration test. K-Factor is
defined as pulses per unit volume, consequently, an Additive K-Factor of 2700 would designate there are
2700 additive pulses per gallon of additive. Calibration testing insures the actual volume dispensed through
the injector is accurately reflected by the unit display. This number is automatically calculated when that
Auto-Calibration feature is used. See Calibration Section 4.
Ch1 Additive Set
- Used to designate the volume of additive, in cc's, per injection request. The
user must calculate the injection rate, in cc's, for the Product Set value programmed. The calculated
injection rate must be entered into the program. Program range 2.0000-9999.9999.
Ch1 Customer ID
- User may enter a unique customer identification number, if desired. Program
range 1-999,999. Alphanumeric entry.
Product Pulse Type
40:1
20:1
1:1
Turbine Meter
Recommended Product K-
Factor
0.025
0.05
1
As Specified On Meter
Product Set
40
40
40
40
Содержание ProPAC-3